Changing Group Of Parameters (Level 2) - Assa Abloy SW100 Installation And Service Manual

Swing door operator
Hide thumbs Also See for SW100:
Table of Contents

Advertisement

14 Advanced settings
14.3

Changing group of parameters (Level 2)

a Disconnect batteries if any.
b Disconnect the mains.
c Press the LEARN BUTTON (LRN) and keep it depressed.
d Connect the mains.
e Watch the ERROR LED.
3 s
f
Release the LEARN BUTTON after 2 flashes (LED is out).
The ERROR LED flashes a number of short flashes that corresponds to the parameter group
number (see table). After a short pause the LED will repeat the group number, and so on.
g Pushing the LEARN BUTTON once, increases the parameter group number. When the highest
parameter group number is reached it will start with number 1 (default) again.
h Push the button until you get the requested parameter group. Ensure that the requested group
of parameters has been selected by counting the number of flashes.
i
Disconnect the mains.
j
Next time the mains is connected, the operator will use the new group of parameters.
Parameter/ Group
1 (default)
OPEN/CLOSE
15 minutes
HOLD OPEN TIME
BATTERY mode
Power Save
KILL mode
Locked dur-
ing KILL
OBSTRUCTION
Door closer
mode
1)
DOUBLE EGRESS
Separate
mode
presence de-
tection
LOCK RETRY
On
OPEN/CLOSE im-
In AUTO
pulse
mode
KILL Impulse
Normally
Configuration
Open
1)
If set to REVERSES WHEN OBSTRUCTED, the operator re-opens when obstructed, similar to a presence impulse.
As default the operator tries to close two times extra in automatic operation, OFF or EXIT mode and one time in manual operation, OFF or
EXIT mode if there is a problem with binding striking plates. This function can be switched off (see LOCK RETRY above).
Note! When changing group of parameters, normally only the primary control must be configured in a double door application. When
changing from or to group seven, both primary and secondary must be configured.
58
1 s
3 s
2
3
Infinite
15 minutes
15 minutes
Power Save
Convenience
Power Save
Locked dur-
Locked during
Lock follows
ing KILL
KILL
program se-
lector during
KILL
Door closer
Door closer
Door closer
Separate
Separate pres-
Separate
presence de-
ence detec-
presence de-
tection
tion
tection
On
On
On
In AUTO
In AUTO
In AUTO
mode
mode
mode
Normally
Normally
Normally
Open
Open
Open
Issue 2021-02-24
4
5
6
15 minutes
15 minutes
Power Save
Power Save
Locked dur-
Locked dur-
ing KILL
ing KILL
Reverses
Door closer
when ob-
structed
Separate
Common
presence de-
presence de-
tection
tection
On
On
In AUTO
In AUTO
mode
mode
Normally
Normally
Open
Open
7
8
15 minutes
15 minutes
15 minutes
Power Save
Power Save
Power Save
Locked dur-
Locked dur-
Lock follows
ing KILL
ing KILL
program se-
lector during
KILL
Door closer
Door closer
Door closer
Separate
Separate
Separate pres-
presence de-
presence de-
ence detec-
tection
tection
tion
Off
On
On
In AUTO
In OFF, EXIT
In AUTO
mode
and AUTO
mode
mode
Normally
Normally
Normally
Open
Open
Closed
1005088-en-22.0
9
10
15 minutes
Convenience
Locked dur-
ing KILL
Reverses
when ob-
structed
Separate
presence de-
tection
On
In AUTO
mode
Normally
Open