ANOMALIES - CAUSES - REMEDIES

The table shows the possible anomalies that can cause a failure and/or irregular
operation of the
generated it and the actions to be taken to restore correct functioning of the appliance
are indicated.
Anomaly
The grinder does
not turn on.
Coffee beans do
not descend from
the supply hopper.
The "Warning"
screen appears on
the display:
74 / 116
coffee grinder. For each anomaly, the possible cause that
Cause
No electric power.
Shutter closed too
much.
The adjustment ring nut
has been released from
its rotation lane and the
safety microswitch (see
Fig. 6 Item 1) does not
detect the removable
chamber in its correct
working position.
Solution
Make sure that the switch is in
the "ON" position;
Make sure that the circuit
breaker upstream of the socket
(if present) is in the ON position.
Make sure that the power
cord is intact and that the plug
is properly connected to the
socket.
Open the shutter.
Correctly tighten the adjustment
ring nut on its rotation lane
following the instructions given
in the "Reassembling the
grinder" point of paragraph
6.1.1.