Pyronix ENFORCER V11 Programming Manual page 55

Hide thumbs Also See for ENFORCER V11:
Table of Contents

Advertisement

NO.
TYPE
0030
Confirmed Hold Up Any
0033
Entry/Exit
0034
Lights
0035
Follow Input
0037
Restore 1
0038
Restore 2
0039
PIR Latch 1
0040
PIR Latch 2
0041
Mains Good
0042
Detr Indn Enable
0043
Follow Test
0044
Off During Test
0048
Detr Walk Test
0049
Detector Masked
(Not applicable on
grade 2 systems)"
0050
Follow 24 Hour
0051
Line Fault
0052
Mains Fail
0053
Battery Faults
0054
Low Volts
0055
"Global Fault 1
(Faults: Modem, Battery,
Fuse, Line, Mains)"
0056
"Global Fault 2
(Faults: as above)"
0058
Guard Code Used
0059
Engineer Access
0060
Initialise Digi
0063
Test ATE/GSM
ACTIVE
When more than one confirmed
hold up activates
Live during any entry or exit time
When exit or entry timer starts
When input triggers
At code entry to set
At code entry to set
When set (and in Walk Test)
This is the inverse polarity to PIR Latch 1
Output showing the mains is healthy
This output activates during walk test and also when a code is entered to
view indications – staying activated for the time for which the indications
are viewed.
New output for alternative bell test by activating SAB
New output for alternative bell test by activating SAB
This output is active during walk test, and will only deactivate when all
detectors have been tested.
If any detector goes into 'mask'
condition the output will trigger
If any input programmed as "Day
alarm" activates
When Line Fault signalled by
communicator
After pre-set time without mains
power
When battery disconnected or load
fail detected
When the input voltage from the
transformer is too low
At fault
Activates if fault occurs only when
system is armed
When 'guard' code accepted
When entering Engineer Mode
At power up
Test signalling through PSTN and
GSM. Activates when a test call is
sent.(Only used for specific GSMs)
ENFORCER V11 PROGRAMMING GUIDE
RESTORE
At next code entry
20 seconds after set/disarmed
procedure completed
Dependent upon programming
After 3 seconds
When disarmed
At alarm, or when disarmed
When masking fault clears.
When input restored
When fault clears
On restoration of mains
At next valid code entry
When the control panel reads the
correct voltage.
When fault clears
When all faults cleared
After 60 seconds
Leaving Engineer Mode
Live for 45 seconds only
When test completed
55