This function is used in conjunction with a reader programmed as 'Entry Control' .
If 'YES' the 'Entry Control' readers will control the arming/disarming and access control. If 'NO' the Entry Control
readers will control the arming/disarming only.
For programming entry control readers, see
"Entry Control or Access Control" on page
23.
Fire Key Enable
If 'YES' the fire key will be enabled on the keypad.
Set With Polling Fault
If 'YES' the system will still arm even if there is a wireless polling fault.
If 'NO' the user will not be able to arm the system with a polling fault. The keypad will display a fault and the
arming procedure will be stopped. The zone causing the poll fault can be identified in the event log.
Fob Unset Entry
If 'YES' any wireless keyfobs learnt will only be able to disarm the system once the entry time has been started. If
'NO' any wireless keyfobs learnt will be able to disarm the system without the entry time being started first.
Wireless Bell Supervision
If 'YES' then wireless external bells will activate they can't communicate with the system for a period of 2 hours.
Download if Set
If 'YES' any upload/download procedures will be possible on the InSite software regardless of the arm/disarm
status of the system.

OCCUPANCY ZONES

This section programs the action(s) the system will take if any zones with the occupancy attribute enabled are not
triggered for the duration of the occupancy timer.
Push notification
If enabled, the system will send a push notification to the smart device application.
Hint: To receive push notifications, this option must be enabled and notification type '284 No Activity in Property' must be activated on the users Cloud
account. This can be found in Notifications > Alarms.
SMS
If enabled, the system will send an SMS to programmed telephone numbers.
Hint: The occupancy alert SMS event is associated with the alarm option in the SMS event menu. If the Alarm option is selected in the SMS event menu,
and if there is no activity, an SMS text message will be sent to the respective mobile phone. To view the categories, see the Communications Guide.
ARC call
If enabled, the system will send a signal to the programmed ARC.
Hint: To signal an occupancy event to an ARC using Fast Format, one of the Digi outputs needs to be programmed as output type '0065 Input Activity Fl' .
Keypad sounder
If enabled, the system will sound all the speakers on keypads and proximity readers.
Internal sounder
If enabled, the system will alert from any internal sounders/speakers on the system.
External sounder
If enabled, the system will sound any external sirens on the system.
For occupancy attribute information, see
"Input Attributes" on page
17.
For the occupancy timer and arm suspension, see
"Change Timers" on page
24.