Pressb or h to scroll to 'DIAGNOSTICS?' . Press .
1.
Press h until 'Communications' is displayed and press .
2.
Please note: For more information, please refer to the Communication Guide.
ENGINEER RESTORE OPTIONS?
The Engineer Restore Options are used so that once an alarm has occurred; the system can only be reset by an
engineer code or anti-code.
Engineer Restore of Intruder
If 'UK Intruder' , an Engineer code must be used to reset the system after an alarm. 'Secure Intruder' should not be
used.
Engineer Restore of Hold Up
If 'YES' , an Engineer code must be used to reset the system after an Hold Up, Zone Hold Up, or Duress activation.
Engineer Restore of Tamper
If 'YES' , an Engineer code must be used to reset the system after a tamper activation.
Engineer Restore of Soak
If 'YES' , an Engineer code must be used to reset the system after a zone that is on 'soak' has triggered when the
system is set.
Engineer Restore of Confirmed
If 'YES' , an Engineer code must be used to reset the system after a confirmed alarm has occurred.
Engineer Restore of Faults
If 'YES' , an Engineer code must be used to reset the system after the following faults:
•
ATE telecom fail
•
Modem fail
•
ATE single path fail
•
Telecom line fail
•
Battery disconnect
•
Batt charge
•
Battery load
•
Excessive charge
•
Battery critical
•
Device fail
Anti-Code Restore
If 'YES' , the system will display an Anti-Code, to which can be used to generate a special reset code (usually from
the ARC) to reset the system.
Please note: If Anti-Code is selected, this will coincide with the options that have been selected
previously. For example, if 'Engineer Restore Intruder' is selected, and Anti-Code is selected, then an anti-
code will be produced on intruder activation.
ENGINEER RESTORE OPTIONS
ENFORCER V11 PROGRAMMING GUIDE
COMMUNICATIONS DIAGNOSTICS