Setting Gain

The gain setting, Mode 0 to Mode 3 and Auto Mode, integrated on the laser module can be
selected. Selecting an optimum gain mode enhances scanning performance especially for a bar
code distanced far away from the terminal and a bar code printed in low resolution ("PCS").
Table 2.48
Gain Mode
• Standard mode
Mode 0
(Default)
This mode generates ordinary scanning performance for bar codes with various printing
qualities and in various scanning conditions.
• Low sensitive mode
Mode 1
This mode enhances scanning performance for bar codes especially with low PCS. However,
for bar codes with other levels of PCS, the mode is not recommended.
• High sensitive mode
Mode 2
This mode enhances scanning performance for bar codes distanced far away from the terminal.
However, for bar codes distanced near the terminal the performance is relatively inferior.
• Super sensitive mode
Mode 3
This mode enhances scanning performance for bar codes with thin white bars or black thin bars
or stained bars. For other conditions, the mode is not recommended.
• Automatic gain change mode
Auto Mode
This mode carries out the gain modes one by one set in the registry below to perform scanning.
If decoding a scanned bar code succeeds in one of the gain modes set in the registry, that gain
mode is memorized and fixed temporarily for subsequent scanning with a few bar codes. This
allows changing gain mode by reducing the deterioration of response from scanning. In this
gain mode, the rate of success in scanning can be improved for bar codes in print quality and
scanning conditions that the gain mode is good at. Contrarily to other gain modes, it may cause
the response from scanning to be worse.
Registry for automatic gain change mode:
Location : [HKEY_LOCAL_MACHINE\Drivers\CASIO\Laser]
Parameter: GainPtn=A (DWORD value)
• Select one of the listed values above for the parameter A. Set a sum of values in the
parameter if you select several modes at a time.
Ex. Modes 0, 1, 2, 3 => Values 8+4+2+1 => 15 => Set "15" in the parameter A.
• Default is 15. The gain mode changes Mode 0 to 3 and then Auto Mode.
• Change made in the registry will be effect by performing a reset on the terminal.
• If the Auto Mode is set without the registry being existed, all the gain modes are
automatically performed one by one.
8 : Gain Mode 3
4 : Gain Mode 2
2 : Gain Mode 1
1 : Gain Mode 0