Settings for Scanning Bar Codes
For each symbology, parameters that can define the scanning performances are specified with its
individual symbology name in the section name (see Table 2.64).
Table 2.64
Item
[Symbology] Section
Enable
Min
Max
Output Start/Stop Code
Read On Check Char
Read On Check Digit
Output Check Char
Output Check Digit
Read On 2 Check Digit
Full ASCII
Only Carrier Message
Append 2Digit Addon
Append 5Digit Addon
Request Addon
Separate Addon
Output System Number
Expand Version E
Description
Sets up "Enable" or "Disable" for scanning a
symbology.
Specifies the minimum no. of digits for scanning a
symbology.
Specifies the maximum no. of digits for scanning a
symbology.
Sets up "Enable" or "Disable" for output of start
and stop codes.
Sets up "Enable" or "Disable" for scanning a
symbology with check character.
Sets up "Enable" or "Disable" for output of check
character.
Sets up "Enable" or "Disable" for scanning a
symbology with 2-digit check character.
Sets up "Enable" or "Disable" for output of Full
ASCII conversion.
Sets up "Enable" or "Disable" for output of carrier
message only.
Sets up "Enable" or "Disable" for output of 2-digit
addon data.
Sets up "Enable" or "Disable" for output of 5-digit
addon data.
Sets up "Enable" or "Disable" for scanning a
symbology only with addon data.
Sets up "Enable" or "Disable" for output addon
data separated with space.
Sets up "Enable" or "Disable" for output of system
number.
Sets up "Enable" or "Disable" for output of
12-digit expanded UPCA symbology.
94
Setting
0; disable, 1; enable
0; disable, 1; enable
0; disable, 1; enable
0; disable, 1; enable
0; disable, 1; enable
0; disable, 1; enable
0; disable, 1; enable
0; disable, 1; enable
0; disable, 1; enable
0; disable, 1; enable
0; disable, 1; enable
0; disable, 1; enable
0; disable, 1; enable

Advertisement