2.1.9 Memory Corruption Check
At a time of reset under WindowsCE OS, RAM data corruption is detected if any. If RAM data
corruption is detected, the memory will be unconditionally initialized without issuing a warning
message to the user.
To prevent this memory initialization without issuing a message, check the status of data used for
memory check in the driver before the process for OS booting up starts up. If a memory
corruption is detected, the following message asking for confirmation of whether it is okay to
implement recovery (reset) will appear.
Figure 2.7
The Trigger R key is pressed to continue the reset of operations (reset). Once the Trigger R key is
pressed while the confirmation message is on the screen, the reset process will be carried out and
the recovery process is attempted.