Configuring SNMP

To configure the Digi CM for SNMP do the following:
1. Access the Digi CM web interface.
2. Under the Network Configuration heading, choose SNMP configuration.
3. Fill in information for the MIB-II system objects section and choose Yes
4. Enter Access control settings.
5. Enter Trap receiver settings.
Chapter 6
Protocol
GET
Queries a device for more information
SET
Makes changes to a device's state
GET-
After an initial GET query, goes to the next value
Next
GET-Bulk
Retrieves tables of information and security functions
TRAP
Notifies a system administrator of a significant event
under EnableAuthenTrap.
sysContact: Identity of the contact person managing the MIB-II system.
sysName: The name identifying the system. By convention, this is the
fully qualified domain name of the Digi CM unit. An example is:
DigiCM@companyname.com.
sysLocation: The physical location of the unit such as Room 264 or
Engineering Lab.
sysService (Read only): A series of values, separated by commas, indi-
cating the set of services the system provides. By default the Digi CM
only supports Application (7) service level.
EnablePowerOnTrap: Determines whether the SNMP agent generates
a trap each time the Digi CM is started.
EnableAuthenTrap: Indicates whether the SNMP agent process is per-
mitted to generate authentication failure traps.
EnableLinkUpTrap: Determines whether the SNMP agent generates a
trap each time the network connection comes up.
Note:
Trap values override all other configuration information, meaning all other authen-
tication failure traps can be disabled with this setting.
IP Address: Defines what applications can access the Digi CM SNMP
agent to exchange information and control actions. If no IP addresses
are listed, any application can access the SNMP agent.
Community: The options are public or private.
Permissions: The options are Read only or Read/Write.