RINSING

1. Close the bleed plug when the radiator is
completely empty. Install the plug on the engine
block.
2. Fill the system with clean water. Install the
radiator cap.
3. Start the engine. Let the engine run in low idle
position for ten minutes to bring the engine
temperature to about 80°C (176° F).
4. Drain the system once more.
5. Repeat Steps 1 to 4 until the water drained is
clear.
6. Install the panel under the upperstructure.

FILLING

1. Fill with coolant solution via the radiator until
overflowing and install the radiator cap.
CT02D022
2. Fill the expansion tank to the Full mark and
install the plug.
IMPORTANT: Use the correct coolant solution.
3. Run the engine at idle speed for about five
minutes. Add coolant solution if the level in the
expansion reservoir drops.
IMPORTANT: Do not fill the expansion tank
above the Full mark.
6-34551NA
CHAPTER 5 - LUBRICATION, FILTERS, AND FLUIDS
Figure 55
Figure 56
Issued 8-04 Bur
CT02D022
Figure 57
5-25