Changing oil
filter 2
After changing
the filter
S
Maintenance manual
GMK4090
Risk of damage to the hydraulic pumps
The engine may only be started if the valve in the suction line of the hydrau-
lic pumps is open and there is enough hydraulic oil in the hydraulic oil tank.
Check the valve on the hydraulic oil tank. Open the valve, if necessary;
à
p. 8 - 44.
Check the oil level. Top up the oil if necessary;
To bleed the system (from the crane cab), start the engine and let it idle
for 3 minutes.
Check that none of the oil filters is leaking.
Release the receptacle (1) at the hexagon
head.
Change the filter (2).
Replace the gaskets.
Fill the receptacle with clean oil and tighten
it – torque 25 Nm (18.5 ft lbf).
3 302 649 en
Maintenance work on the superstructure
8.6 Hydraulic system
à
p. 8 - 43.