Connecting the Replenisher Tanks and Strainers
• Installations may use internal or
external REPLENISHER TANKS or a
chemical mixing system, such as a
Kodak AUTOMIXER III.
• Use the manufacturer's installation
instructions to install a chemical mixing
system.
[1]
Place the customer's REPLENISHER TANKS
or chemical mixing system in position and
3
connect. Use ⁄
8
No. 452990, which you can order by the foot.
[2]
Install the STRAINERS in the lines between
the PROCESSOR and the REPLENISHER
TANKS or chemical mixing system. See
Figure 23.
[3]
Connect the replenishment lines correctly to
the feed end of the PROCESSOR. See
Figures 21 and 23.
2B6843
NOTE
in. ID tubing, Part
Figure 23 Connecting the Replenisher Strainers
internal
REPLENISHER TANK
Figure 22 Installing Internal Replenisher Tanks
STRAINERS
H104_0032ACA
H104_0032AA
external
REPLENISHER TANK
H104_0026BCA