Applying Multiple Weld Schedules (continued)
Setting the Opening and Closing of Shutters
Selection With the Control
Pendant. For this selection mode, the EXT-
ON circuit at the EXT. I/O (1) connector is
open (see Chapter 3).
1.
Press the MENU key to access the
status screen.
2.
Set the branch shutters that you wish
to open to :ON. For example, if you
open Branch Shutter No. 1 by changing SHUTTER-1:OFF to SHUTTER_1:ON, The
SHUTTER 1 indicator will turn on and Laser Bean Input Unit 1 will be selected.
990-605 REV B: May, 1997
CHAPTER 6: OPERATING INSTRUCTIONS
Figure 6-9. Laser Output With Waveform Control
When blocking the laser beam with a branch
shutter, limit the laser beam power to 10 Joules
once in 1.7 seconds, and 6 watts.
LW250 PULSED Nd: YAG LASER
CAUTION
-STATUS [PANEL CONTROL]
SHUTTER-1:OFF
SHUTTER-2:OFF
SHUTTER-3:OFF
SHUTTER-4:OFF
HV:OFF MAIN SHUTTER:OFF POSITION:OFF
L25WCONT.WPG
WATER
° C
ROM VERSION
[
[
POSITION BLINK: OFF
]
]
6-11