Laser Output (continued)
High Speed Operation, FLASH1
and VOLT B are set to approximately the same amplitude, the laser output becomes larger, but
the second (FLASH2) shot cannot be emitted immediately after FLASH1. So, you must set the
schedule with VOLT A essentially equal to VOLT B as follows (refer to Figure 6-5):
[
Schedule 1]
-SCH.#01
FLASH1
COOL1
FLASH2
COOL2
FLASH3
A=300V*
*A and B set almost equal
990-605 REV B: May, 1997
CHAPTER 6: OPERATING INSTRUCTIONS
Figure 6-4. Laser Output Control
Examples of Setting VOLT A
TIME
VOLT
10.0ms
A
00.0ms
00.0ms
A (or B)
00.0ms
00.0ms
A (or B)
B=301V*
LW250 PULSED Nd: YAG LASER
FLASH2. As previously described, if VOLT A
VOLT B
[Schedule 2]
-SCH.#02
TIME
FLASH1
10.0ms
COOL1
00.0ms
FLASH2
00.0ms
COOL2
00.0ms
FLASH3
00.0ms
A=300V*
B=301V*
*A and B set almost equal
L25LOUT.WPG
VOLT
B
A (or B)
A (or B)
6-6