Gas Burner Coils; Burner Ignitor - Kenmore Oasis 110.67032600 Manual

Electric & gas dryer
Table of Contents

Advertisement

Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.

GAS BURNER COILS

4 5
Refer to page 4-12 for the procedure for ac-
cessing the gas burner assembly.
1.
Unplug dryer or disconnect power.
2.
Turn off gas supply to dryer.
3.
Disconnect the wire connectors from the
coil terminals.
4.
Set the ohmmeter to the R x 100 scale.
5.
Touch the ohmmeter test leads to the
2-terminal coil. The meter should indicate
between 1000 and 1300 Ω.
6.
Touch the ohmmeter test leads to the
3-terminal coil. The meter should indicate
as follows:
Pins 1 & 2 = 1300 to 1400 Ω
Pins 1 & 3 = 500 to 600 Ω
Burner
Coils
1
2
3
Electrical Shock Hazard

BURNER IGNITOR

Burner Ignitor
Refer to page 4-12 for the procedure for ac-
cessing the gas burner assembly.
1.
Unplug dryer or disconnect power.
2.
Turn off gas supply to dryer.
3.
Disconnect the ignitor wire connector
from the main harness connector.
4.
Set the ohmmeter to the R x 1 scale.
5.
Touch the ohmmeter test leads to the
2-wire connector pins. The meter should
indicate between 50 and 500 Ω.
5-3
2 Wire Connector

Hide quick links: