REMOVING THE HIGH-LIMIT THERMOSTAT & INLET
THERMISTOR, THERMAL CUTOFF, AND ELECTRIC HEATER
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug dryer or disconnect power.
2.
Remove the cabinet front (see page 4-6
for the procedure).
3.
Remove the belt and drum from the dryer
(see page 4-15 for the procedure).
Electric Heater, High-Limit Thermostat,
Inlet Thermistor, & Thermal Cutoff
(ELECTRIC MODELS ONLY)
4-10
4.
Remove the 5/16˝ hex-head screw from
the mounting bracket.
Heater Housing Bracket Screw
5.
To remove the high-limit thermostat &
inlet thermistor:
a) Remove the two wires from the ther-
mostat terminals.
b) Unlatch and pull the 2-wire connector
out of the inlet thermistor housing.
c) Remove the two hex-head screws
from the high-limit thermostat/inlet
thermistor.
6.
To remove the thermal cutoff:
a) Remove the two wires from the ther-
mal cutoff terminals.
b) Remove the two hex-head screws.
Thermal Cutoff
Inlet Thermistor
High-Limit Thermostat
Heater Terminal Block