Diagnostic Guide; Unsuccessful Entry; Saved Fault Codes; Diagnostic Tests - Kenmore Oasis 110.67032600 Manual

Electric & gas dryer
Table of Contents

Advertisement

DIAGNOSTIC GUIDE

Before servicing, check the following:
Make sure there is power at the wall out-
let.
Has a household fuse blown or circuit
breaker tripped? Time delay fuse?
Is dryer vent properly installed and clear of
lint or obstructions?
All tests/checks should be made with a
VOM (volt-ohm-milliammeter) or DVM
(digital-voltmeter) having a sensitivity of
20,000 ohms per volt DC or greater.
Check all connections before replacing
components. Look for broken or loose
wires, failed terminals, or wires not pressed
into connectors far enough.
A potential cause of a control not function-
ing is corrosion on connections. Observe
connections and check for continuity with
an ohmmeter.
Connectors: Look at top of connector.
Check for broken or loose wires. Check
for wires not pressed into connector far
enough to engage metal barbs.
Resistance checks must be made with dry-
er unplugged or power disconnected.

DIAGNOSTIC TESTS

These tests allow factory or service person-
nel to test and verify all inputs to the machine
control electronics. You may want to do a
quick and overall checkup of the dryer with
these tests before going to specific trouble-
shooting tests.
ACTIVATING THE DIAGNOSTIC
TEST MODE
1.
Be sure the dryer is in standby mode
(plugged in with all indicators off, or with
only the Clothes Dry indicator on).
2.
Select any one button (except Stop) and
follow the steps below, using the same
button (remember the button):
Press/hold
Release for
Press/hold
3 seconds
3 seconds
3 seconds
Release for
Press/hold
3 seconds
3 seconds
6-2
3.
If this test mode has been entered suc-
cessfully, all indicators on the console
are illuminated for 5 seconds with 88
showing in the Estimated Time Remain-
ing two-digit display.
DIAGNOSTIC: Unsuccessful Entry
If entry into diagnostic mode is unsuccessful,
press the Stop button twice, then press the
Power button.
If indicators come on, try to use a different
button than was used to activate the diag-
nostic test mode. If that button fails to enter
the diagnostic mode, something is faulty,
and it is not possible to enter the diagnostic
mode. Go to TEST #2.
If no indicators come on after pressing the
Power button, go to TEST #1.
DIAGNOSTIC: Saved Fault Codes
If there are saved fault codes, the most recent
fault code will alternately show "F-" and "XX"
where XX is the fault code.
Press and release
the same button
beep tone
used to activate
Diagnostics
Repeat
beep tone
Repeat
beep tone
Repeat
All indicators momentarily turn off, then stay on.
DIAGNOSTIC: Console Buttons
And Indicators
Pressing buttons and rotating the cycle se-
lector will turn off the corresponding indica-
tor and sound a beep as shown in Figure 2.
Pressing MORE TIME will toggle the left digit
on the display while sounding a beep. Press-
ing LESS TIME will toggle the right digit on
the display while sounding a beep.
If indicators fail to come on and beep after
pressing buttons and rotating the cycle se-
lector, go to TEST #6.
Second most recent fault code is displayed.
Third most recent fault code is displayed.
Fourth most recent fault code is displayed.

Hide quick links: