REMOVING THE THERMAL FUSE & OUTLET THERMISTOR
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug dryer or disconnect power.
2.
Turn off gas supply to dryer.
3.
Remove the cabinet front (see page 4-6
for the procedure).
4.
To remove either the thermal fuse or
the outlet thermistor:
a) Remove the two wires from the termi-
nals.
b) Remove the two 5/16˝ hex-head
screws.
Outlet Thermistor
Thermal Fuse
4-9
Blower Fan Housing