CHANGE GAS SETTING (NATURAL GAS, PROPANE GAS)

Warning
!
STEP 1 : VALVE SETTING
Opened
Full open
Adjustment screw
STEP 2 : ORIFICE CHANGE
Orifice
Changing orifices and gas valve adjustments improperly can result in an
explosion and/or fire. Conversion must be made by a qualified technician.
Initially
, Natural Gas mode is set. Propane Gas Orifice is on sale as a Service
Part to authorized servicers only.
Closed
Close
Adjustment screw
Remove 2 screws.
Disassemble the pipe assembly.
Replace Natural Gas orifice with Propane Gas orifice.
Gas type
Orifice P/No
Natural Gas
4948EL4001B
Propane Gas
4948EL4002C
Kit contents: Orifice (Dia. = 1.470mm, for Propane Gas)
Replace Label
Instruction Sheet
37
Shape
Marking
NCU