Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
HIGH-LIMIT THERMOSTAT, INLET
THERMISTOR, & THERMAL CUTOFF

(ELECTRIC MODELS ONLY)

Thermal Cutoff
Inlet Thermistor
High-Limit
Thermostat
Refer to page 4-10 for the procedure for ac-
cessing the high-limit thermostat, inlet therm-
istor, & thermal cutoff.
1.
Unplug dryer or disconnect power.
2.
Disconnect the wires or connector from
the component under test.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the
high-limit thermostat terminals. The me-
ter should indicate a closed circuit (0 Ω).
NOTE: The thermostat opens at 295°F
(146°C).
5.
Touch the ohmmeter test leads to the
thermal cutoff (TCO) terminals. The me-
ter should indicate a closed circuit (0 Ω).
NOTE: The TCO opens at 352°F (178°C).
6.
Set the ohmmeter to the R x 100K scale.
7.
Touch the ohmmeter test leads to the inlet
thermistor terminals. The meter should in-
dicate approximately 50k Ω @ 69 to 86°F
(21 to 30°C).
Electrical Shock Hazard

ELECTRIC HEATER

Heater Terminal Block
Refer to page 4-10 for the procedure for ac-
cessing the electric heater.
1.
Unplug dryer or disconnect power.
2.
Disconnect the wires from the heater ter-
minal block.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the heat-
er terminals. The meter should indicate be-
tween 7 and 12 Ω.