Filling port

The filling hose and the front connection on the
spraying mixture container are equipped with
couplings that can only be connected or discon-
nected when both valves are closed. The lock is
blocked when the valves are open.
The prevents spraying mixture from draining.
C
A
Hose couplings
A Coupling/valve tank side
B Coupling/valve filling hose
C Interlocking
D Lever to release the lock
To connect, slide the couplings into each other
and allow the lock to engage securely.
To disconnect, lift the levers to release the
¾
lock and pull the couplings apart.
Also fit the crop protection sprayer to be filled
¾
and hoses from filling stations with these hose
couplings.
36
D
B
D
C

Filling via filling port

CAUTION
Damage caused by overfilling the closed spray-
ing mixture container.
Keep the lid open while filling.
¾
Watch the filling level indicator to avoid over-
¾
filling the spraying mixture container.
Pay attention to the applicable regulations for
¾
filling the spraying mixture container through the
suction hose from open water taps.
B
A
Pump and operating elements
A Main filling valve
B Fitting valve
C Lever for speed control of the delivery pump
1. Connect the filling hose.
2. Open valve A.
3. Close valve B.
4. Turn the lever 7 up to Suction for the pump
to suck.
5. Always watch the TankControl filling level
indicator while filling.
6. Stop filling the spraying mixture container at
the latest
when the filling limit is reached.
¾
before the permissible payload of the
¾
carrier vehicle is exceeded by the filled in
amount of liquid.
the content of the spraying mixture con-
¾
tainer still rises when flushing in crop
protection agent. Calculate a reserve
therefore when filling.