5 Additional Information

5.1 Dual (Intensity + Distance) Mode

In background suppression (DYN, 1-pt, 2-pt) and foreground suppression (FGS) TEACH modes, the Q5X sensor compares
changes in the measured distance between the sensor and target to control the output state. Dual TEACH mode, dual
intensity + distance window, expands the applications the Q5X can solve by combining distance-based detection with light
intensity thresholds. In dual TEACH mode, the user teaches the Q5X a fixed reference surface, and the sensor compares
intensity and distance readings against the reference surface it was taught. After teaching the reference target, the
displayed value is calibrated to 100P, or a 100% match. When an object enters the sensor's field of view, the degree of
consistency with the reference surface becomes lower and causes a change in sensor output.
In dual mode, you can detect when the target is present at the right distance and when it returns the right amount of light.
This is useful in error-proofing applications where you need to know not only that the part is present (distance), but also that
it is the correct part (intensity).
In dual mode, the Q5X requires a reference surface (far left). Once taught, the distance and intensity of the reference surface
are recorded and used as a baseline. A user-adjustable switching threshold is set, and changes in distance and/or intensity
outside the switching threshold creates a sensor output change. The example uses a 90% (90P) match condition with a
10% change in intensity and/or distance from the reference surface required to change the output state. The default-
switching threshold is a 50% match to the reference condition (50P); this sets the threshold 50% from the distance and
intensity of the reference surface. A transparent object can be detected either by a change in intensity, distance, or by a
double peak reflection (far right).
Reference Condition
100% matched distance + Intensity after Dual teach
120
120
110
110
100
100
90
80
10% Switching
70
Threshold
60
50
40
30
20
10
0
0
25
50
75
100 125 150 175 200 225 250 275 300
Distance (mm)
The Q5X sensor can be taught non-ideal reference surfaces, such as surfaces outside of the sensor's range, very dark
surfaces, or even empty space. These situations may enable applications requiring a long range detection but are subject to
typical diffuse mode detection challenges.

5.2 Dual Mode Reference Surface Considerations

Optimize reliable detection by applying these principals when selecting your reference surface, positioning your sensor
relative to the reference surface, and presenting your target. The robust detection capabilities of the Q5X allows successful
detection even under non-ideal conditions in many cases. Typical reference surfaces are metal machine frames, conveyor
side rails, or mounted plastic targets. Contact Banner Engineering if you require assistance setting up a stable reference
surface in your application.
1. Select a reference surface with these characteristics where possible:
Matte or diffuse surface finish
Fixed surface with no vibration
Dry surface with no build-up of oil, water, or dust
2. Position the reference surface between 200 mm (20 cm) and the maximum sensing range.
3. Position the target to be detected as close to the sensor as possible, and as far away from the reference surface as
possible.
4. Angle the sensing beam relative to the target and relative to the reference surface 10 degrees or more.
5.3 Dual Mode Considerations for Clear and Transparent Object
Detection
The Q5X is able to detect the very small changes caused by transparent and clear objects. A transparent object can be
detected either by a change in intensity, distance, or by a double-peak reflection.
Change in Intensity
Output switches with intensity change
120
110
100
90
90
80
80
70
70
60
60
50
50
40
40
30
30
20
20
10
10
0
0
0
25
50
75
100 125 150 175 200 225 250 275 300
0
Distance (mm)
Figure 28. Dual Mode Example
www.bannerengineering.com - Tel: + 1 888 373 6767
Q5X Laser Triangulation Sensor with Dual Mode for Jam Detection
Change in Distance
Change in Distance and Intensity
Output switches with distance change
Output switches with intensity and distance change
120
110
100
90
80
70
60
50
40
30
20
10
0
25
50
75
100 125 150 175 200 225 250 275 300
0
25
Distance (mm)
Reduced Intensity and/or Second Peak
Output switches with intensity and/or second peak (Clear Object Detection)
120
110
100
90
80
70
60
50
40
30
20
10
0
50
75
100 125 150 175 200 225 250 275 300
0
25
50
Distance (mm)
75
100 125 150 175 200 225 250 275 300
Distance (mm)
37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Q5xklaf2000-q8-jam

Table of Contents