Laser Description And Safety Information; Installation; Sensor Orientation - Banner Q4X Quick Start Manual

Stainless steel laser sensor with dual discrete outputs and io-link
Hide thumbs Also See for Q4X:
Table of Contents

Advertisement

(SELECT)(TEACH)
• Press to select menu items in Setup mode
• Press and hold for longer than 2 seconds to start the currently
selected TEACH mode (the default is two-point TEACH)
(-)(MODE)
• Press to navigate the sensor menu in Setup mode
• Press to change setting values; press and hold to decrease
numeric values
• Press and hold for longer than 2 seconds to enter Setup mode

Laser Description and Safety Information

CAUTION:
• Return defective units to the manufacturer.
• Use of controls or adjustments or performance of procedures other than those specified herein may result in
hazardous radiation exposure.
• Do not attempt to disassemble this sensor for repair. A defective unit must be returned to the manufacturer.
≤ 510 mm Models - IEC 60825-1:2007 Class 1 Laser
Class 1 lasers are lasers that are safe under reasonably foreseeable conditions of operation, including the use of optical instruments for intrabeam
viewing.
Laser wavelength: 655 nm
> 510 mm Models - IEC 60825-1:2014 Class 1 Laser
Class 1 lasers are lasers that are safe under reasonably foreseeable conditions of operation, including the use of optical instruments for intrabeam
viewing.
COMPLIES WITH 21 CFR 1040.10 AND 1040.11
EXCEPT FOR CONFORMANCE WITH
IEC 60825-1:2014, AS DESCRIBED IN
LASER NOTICE No. 56, DATED MAY 8, 2019.
BANNER ENGINEERING CORP.
9714 10TH AVENUE NORTH
MINNEAPOLIS, MN 55441
Laser wavelength: 655 nm

Installation

Install the Safety Label
The safety label must be installed on Q4X sensors that are used in the United States.
Note: Position the label on the cable in a location that has minimal
chemical exposure.
1. Remove the protective cover from the adhesive on the label.
2. Wrap the label around the Q4X cable, as shown.
3. Press the two halves of the label together.

Sensor Orientation

Optimize detection reliability and minimum object separation performance with correct sensor-to-target orientation. To ensure reliable detection,
orient the sensor as shown in relation to the target to be detected.
2
(+)(CH1/CH2)
• Press to navigate the sensor menu in Setup mode
• Press to change setting values; press and hold to increase
• Press and hold for longer than 2 seconds to switch between
Output: < 0.20 mW
CLASS 1
LASER PRODUCT
COMPLIES WITH IEC 60825-1:2014
Output: < 0.39 mW
Figure 5. Optimal Orientation of Target to Sensor
www.bannerengineering.com - Tel: + 1 888 373 6767
Q4X Stainless Steel Laser Sensor with Dual Discrete Outputs and IO-Link
numeric values
Channel 1 and Channel 2
Note: When navigating the menu, the menu items
loop.
Pulse Duration: 7 µs to 2 ms
Pulse Duration: 7 µs to 2 ms
Figure 4. Safety Label Installation
COMPLIES WITH 21 CFR 1040.10 AND 1040.11
EXCEPT FOR DEVIATIONS PURSUANT TO
LASER NOTICE No. 50, DATED JUNE 24, 2007.
BANNER ENGINEERING CORP.
9714 10TH AVENUE NORTH
MINNEAPOLIS, MN 55441
CLASS 1
LASER PRODUCT
COMPLIES WITH IEC 60825-1:2007
P/N 190073 Rev. G