Q5X Laser Triangulation Sensor with Dual Mode for Jam Detection
Output Indicator
•
On—Output is on
•
Off—Output is off
Stability Indicator (STB)
•
On—Stable signal within the specified sensing range
•
Flashing—Marginal signal, the target is outside the
limits of the specified sensing range, or a multiple
peak condition exists
•
Off—No target detected within the specified sensing
range
1.4.2 Buttons
Use the sensor buttons (SELECT)(TEACH), (+)(CH1/CH2), and (-)(MODE) to program the sensor.
(SELECT)(TEACH)
•
Press to select menu items in Setup mode
•
Press and hold for longer than 2 seconds to start the
currently selected TEACH mode (the default is Jam
Retroreflective TEACH)
(-)(MODE)
•
Press to navigate the sensor menu in Setup mode
•
Press to change setting values; press and hold to
decrease numeric values
•
Press and hold for longer than 2 seconds to enter
Setup mode
6
Active TEACH Indicators (FLO, RET, BGS)
•
•
•
•
•
•
•
(+)(CH1/CH2)
•
•
•
www.bannerengineering.com - Tel: + 1 888 373 6767
RET on—Jam Retroreflective TEACH mode selected
(default)
BGS on—Jam Background Suppression TEACH
mode selected
RET and BGS on—Foreground suppression TEACH
mode selected
BGS and FLO on—Background suppression TEACH
mode selected
FLO and RET on—Dynamic TEACH mode selected
RET, FLO, and BGS all off—Two-point TEACH mode
selected
RET, FLO, and BGS all on—Dual TEACH mode
selected
Press to navigate the sensor menu in Setup mode
Press to change setting values; press and hold to
increase numeric values
Press and hold for longer than 2 seconds to switch
between Channel 1 and Channel 2
Note: When navigating the menu, the
menu items loop.