Changing the Additional SEP Settings

You can change four additional SEP settings:
Polling Interval—Controls the interval (in seconds) at which
I
that the controller polls the SEPs for status changes. The default
setting is five seconds.
Temperature Sensor Status—Controls whether the controller's
I
onboard temperature sensor provides temperature information
to the host along with the RAID appliance's temperature as
detected by the SEP. The default setting is OFF, which means
that neither the controller nor the appliance is providing
temperature information to the host.
Slot Flags (Slot update status)—Controls whether the controller
I
sends commands to the SEP to update the status of each storage
enclosure slot. The default setting is ON, which means that the
controller requests status updates from the storage enclosure.
Global Flags (Enclosure update status)—Controls whether the
I
controller sends commands to the SEP to update the overall
status of the storage enclosure. The default setting is OFF, which
means that the controller does not request status updates from
the storage enclosure.
Managing Disk Drives and Enclosures
Do This:
Type NONE and press Enter
I
Type the LUN you want to use
I
and press Enter.
This can be any number from 0
to 63 that is not already in use.
Table 6-1
for
6-9