2
Select New Sample Rate and press Enter.
The New Sample Rate prompt appears.
3
Type the sample rate and press Enter.

Understanding the Audible Alarm

When the controller becomes too hot, or detects low or high
voltage, an audible alarm sounds and an event message appears in
the Adaptec Disk Array Administrator window and in the event
log.
Warning events are generated when the temperature or voltage
enters the warning range. Shutdown events are generated when
the temperature or voltage enters the shutdown range.
Table 5-2
shows the temperature and voltage thresholds for each
alarm and what to do to resolve the problem. Refer to the DuraStor
6200S External RAID Controller Installation Guide for more details.

Changing the Alarm Mute Setting

You can enable the Mute setting on the audible alarm so that you
can turn it off when it is sounding.
1
From the System Menu, select Configuration Menu and press
Enter.
The Configuration menu appears.
2
Select Alarm Mute and press Enter.
The Alarm Mute menu appears. The current setting is marked
with an * next to it.
3
Select Unmute and press Enter.
You can disable the Mute setting by repeating the steps above
and selecting Mute.
Configuring the Controller
5-16