Operation; Manual Operation; Manual Operation: Engage; Manual Operation: Disengage - AUMA SQV 05.2 Operation Instructions Manual

Part-turn actuators
Table of Contents

Advertisement

SQV 05.2
SQV 14.2 / SQRV 05.2
ACV 01.2 Non-Intrusive Profibus DP
7.

Operation

7.1.

Manual operation

7.1.1.

Manual operation: engage

7.1.2.

Manual operation: disengage

7.2.

Motor operation

7.2.1.

Operating the actuator from local controls

SQRV 14.2 Control unit: electronic (MWG)
For purposes of setting and commissioning, in case of motor or power failure, the
actuator may be operated manually. Manual operation is engaged by an internal
change-over mechanism.
Damage at the motor coupling due to faulty operation!
Engage manual operation only during motor standstill.
1.
Press push button.
2.
Turn handwheel in desired direction.
To close the valve, turn handwheel clockwise:
Drive shaft (valve) turns clockwise in direction CLOSE.
Manual operation is automatically disengaged when motor is started again. The
handwheel does not rotate during motor operation.
Valve damage due to incorrect basic setting!
Prior to electric actuator operation, perform the basic settings for "type of seating"
and "torque switching".
Local actuator operation is performed using the local controls push buttons of actuator