AUMA SQV 05.2 Operation Instructions Manual page 74

Part-turn actuators
Table of Contents

Advertisement

Technical data
Features and functions
Splined coupling for connection to
the valve shaft
Valve attachment
Mit Fuß und Hebel (Option)
Schwenkhebel
Kugelgelenke (Option)
Befestigung
Electronic control unit
Non-Intrusive setting
Position feedback signal
Torque feedback signal
Running indication
Heater in switch compartment
Service conditions
Use
Mounting position
Installation altitude
Ambient temperature
Humidity
Enclosure protection according to
EN 60529
Pollution degree according to
IEC 60664-1
Corrosion protection
Coating
Colour
Lifetime
Sound pressure level
74
SQV 05.2
SQV 14.2 / SQRV 05.2
Standard:
Coupling without bore
Options:
Machined coupling with bore and keyway, square bore or bore with two-flats according to
EN ISO 5211
Dimensions according to EN ISO 5211 without spigot
Aus Sphäroguss mit zwei oder drei Bohrungen zum Befestigen eines Gestänges. Der Hebel kann über
eine Kerbverzahnung, unter Berücksichtigung der äußeren Gegebenheiten, in beliebiger Lage auf die
Antriebswelle montiert werden.
Zwei Kugelgelenke, passend zu Hebel, einschließlich den Kontermuttern und zwei Anschweißenden
passend zu Rohr nach Maßblatt.
Fuß und vier Bohrungen für Befestigungsschrauben
Magnetic limit and torque transmitter (MWG)
Via actuator controls
Via actuator controls
Blinking signal via actuator controls
Resistance type heater with 5 W, 24 V AC
Indoor and outdoor use permissible
Any position
≤ 2,000 m above sea level
> 2,000 m above sea level on request
Refer to actuator name plate
Up to 100 % relative humidity across the entire permissible temperature range
Standard:
IP68
Refer to name plates at motor and actuator for exact version
Option:
DS terminal compartment additionally sealed against interior of actuator (double sealed)
According to AUMA definition, enclosure protection IP68 meets the following requirements:
Depth of water: maximum 8 m head of water
Duration of continuous immersion in water: Max. 96 hours
Up to 10 operations during immersion
Modulating duty is not possible during immersion
Pollution degree 4 (when closed), pollution degree 2 (internal)
Standard:
KS: Suitable for use in areas with high salinity, almost permanent condensation, and high
pollution.
Option:
KX: Suitable for use in areas with extremely high salinity, permanent condensation, and
high pollution.
Double layer powder coating
Two-component iron-mica combination
Standard:
AUMA silver-grey (similar to RAL 7037)
Option:
Available colours on request
AUMA part-turn actuators meet or exceed the lifetime requirements of EN 15714-2. Detailed information
can be provided on request.
< 72 dB (A)
SQRV 14.2 Control unit: electronic (MWG)
ACV 01.2 Non-Intrusive Profibus DP