Chapter 10 Troubleshooting

Remedy of defects

In this chapter, possible error causes and their elimination are described.

Failures at the Labeling system

Failure
Low Label Prewarning
Label End
Failure Web Break
Failures at the Labeling System
Failure
Powered motor is not
operating.
Label web is not transported.
Label web runs through.
Faulty Labeling.
Extraordinary Noises.
Version: 02.08.12
Cause
The label material runs out.
The label material has run out.
Label web is torn.
Cause
Connection power is missing.
Fuse defect.
Transport roller or friction roller stick
together with labels.
Friction rollers have no contact to each
other.
Contact pressure of friction rollers is
too low.
Label detection is not correctly
adjusted.
Light barrier is dirty.
Applying pulse is adjusted wrongly.
Foreign material (tool etc.) is in
system.
Loose parts.
Page 69 of 71
32708732 Geset 121
Remedy
Exchange the label
material in due time.
Load new label material.
Load new label web,
control label web mobility.
Adjust light barrier to new
label web.
Remedy
Check connection power.
Replace fuse.
Clean transport roller resp.
friction roller.
Push friction rollers against
each other.
Re-adjust contact pressure.
Adjust label detection.
Clean receiver and
transmitter of the light
barrier.
Check adjustment of
product detection.
Remove foreign material,
check mountings.

Advertisement