Chapter 9 Maintenance

Inspection- and maintenance list

Requirements
The labeling station is without power (no electrical power or compressed air)
The product is not being transported
All maintenance works at the system have to be documented. Due to individual production
conditions, discrepancies may arise that render it necessary to correct the mentioned
intervals accordingly.

Daily servicing (after approximately 8 hours of operation)

Run.
Work to be arranged
No.
1
Examine machine for outside perceivable defects and damages.
Operating Personnel
2
Arrange controls:
Operator panels and -elements:
Controllers.
Expert
3
Safety check!
Push emergency stop pushbutton and main switch.
Machine has to turn off and stop immediately when one of the
emergency pushbuttons is pushed or if you turn the MAINSWITCH
to position "0".
Electrician, Expert
Covers have to be installed and with inserted nuts.
Expert
The safety notes have to be placed
Electrician, Expert
The switch cabinets have to be locked safely.
Electrician, Expert
Visual control: In an on the machine there may not stored any parts
that do not belong to the system.
Expert
Version: 02.08.12
Visual inspection.
Visual- and function inspection.
Page 57 of 71
32708732 Geset 121
Measurement
Test statistic
Lubricant
Perceivable damages
Function, condition,
adjustment values
Function
Function, installation
Availability
Locking
Order

Advertisement