Mechanical Installation; Unpacking; Items Supplied; Storage - Danfoss VLT Decentral Drive FCD 302 Operating Manual

Hide thumbs Also See for VLT Decentral Drive FCD 302:
Table of Contents

Advertisement

VLT® Decentral Drive FCD 302
Operating Guide

3 Mechanical Installation

3.1 Unpacking

3.1.1 Items Supplied

The packaging contains:
Accessories bag, supplied only with order of installation box. The bag contains:
-
2 cable clamps.
-
Bracket for motor/loads cables.
-
Elevation bracket for cable clamp.
-
Screw 4 mm, 20 mm.
-
Thread forming 3.5 mm, 8 mm.
Operating Guide.
Drive.
Depending on options fitted, the box contains 1 or 2 bags and 1 or more booklets.
Make sure that the items supplied and the information on the nameplate correspond to the order confirmation.
Check the packaging and the drive visually for damage caused by inappropriate handling during shipment. File any claim for
damage with the carrier. Retain damaged parts for clarification.
Decentral Drive
VLT®
www.danfoss.com
1
T/C: FCD302P1K5T4W66H1X1XMFCFXXXXA0BXXXXXXDX
2
P/N: 131Z5118
S/N: 000000G000
4
1.5kW(400V) / 2.0HP(460V)
5
IN: 3x380-480V 50/60Hz, 3.7/3.1A
6
OUT: 3x0-Vin 0-590Hz, 4.1/3.4A
7
IP66 Enclosure Tamb. 40 ˚C/104 ˚F
9
1
Type code
2
Ordering number
3
Serial number
4
Power rating
5
Input voltage, frequency, and current (at low/high
voltages)
LOSS OF WARRANTY
Do not remove the nameplate from the drive.

3.1.2 Storage

Ensure that the requirements for storage are fulfilled, see
Danfoss A/S © | 2020.07
10
Enclosure rating:
Type 4X Indoor Use Only
LISTED E134261 76X1 IND. CONT. EQ.
3
8
Danfoss A/S
6430 Nordborg
Denmark
MADE IN DENMARK
N O T I C E
7.4.1
6
Output voltage, frequency, and current (at low/high
voltages)
7
Enclosure type and IP rating
8
Maximum ambient temperature
9
Certifications
10
Enclosure rating
Environment.
Mechanical Installation
AQ267036816112EN-000101 / 130R0208 | 13

Advertisement

Table of Contents
loading

Table of Contents