Operating Guide
Illustration 6: Allowed Mounting Positions - Hygienic Applications

3.3.3.1 Mounting the Installation Box

ELECTRICAL HAZARD
Applying power to the unit at this stage could result in death or serious injury.
-
Do not apply power before the electrical installation is complete.
PERSONAL INJURY OR PROPERTY DAMAGE
Do not switch on the mains before the 4 screws are tightened. Failure to tighten these screws can result in personal injury or
material damage when the unit is loaded.
-
Tighten screws before switching on power.
-
Ensure that the strength of the mounting location can support the unit weight.
Use the holes on the rear of the installation box to fix mounting brackets.
Use proper mounting screws or bolts.
For hygienic versions, use cable glands designed to meet hygienic application requirements, for example Rittal HD
2410.110/120/130.
1.
Mount the VLT® Decentral Drive FCD 302 vertically on a wall or machine frame. For hygienic versions ensure that liquids
drain off the enclosure and orient the unit so the cable glands are located at the base.
16 | Danfoss A/S © | 2020.07
W A R N I N G
W A R N I N G
Mechanical Installation
AQ267036816112EN-000101 / 130R0208