Pu Operation Interlock; Operation Availability In Each Operation Mode; Fl Remote Communication - Mitsubishi Electric 700 Series Instruction Manual

Hide thumbs Also See for 700 Series:
Table of Contents

Advertisement

4.5.2

PU operation interlock

The PU operation interlock function is designed to forcibly change the operation mode to the Network operation mode
when the PU operation interlock signal (X12) input turns OFF.
This function prevents the operation mode from being accidentally unswitched from the PU operation mode. If the
operation mode is left unswitched from the PU operation mode, the inverter does not reply to the commands sent through

FL remote communication.

X12 Signal
Operation mode (PU, NET) switching enabled
ON
Output stop during Network operation
Forcibly switched to Network operation mode
OFF
Network operation allowed
Switching between the PU operation mode is enabled
<
Function/operation changed by switching ON-OFF the X12 signal
Operating Condition
Operation
Status
mode
During stop
PU
Running
During stop
Network
Running
∗1
The operation mode switches to the Network operation mode independently of whether the start signal (STF, STR) is ON or OFF. Therefore, the
motor is run in Network operation mode when the X12 signal is turned OFF with either of STF and STR ON.
∗2
At fault occurrence, pressing
NOTE
If the X12 signal is ON, the operation mode cannot be switched to the PU operation mode when the start signal (STF,
STR) is ON.
4.5.3

Operation availability in each operation mode

Operation availability in each operation mode is shown below.
(Monitoring and parameter read can be performed from any operation regardless of operation mode.)
Operation Location
Item
Run command (start)
Run command (stop)
Operation panel
Running frequency setting
Parameter write
Inverter reset
Run command (start)
Run command (stop)
FL remote communication
Running frequency setting
Parameter write
Inverter reset
∗1
Some parameters may be write-disabled according to the Pr. 77 Parameter write selection setting and operating status. (Refer to page 166)
∗2
Some parameters are write-enabled independently of the operation mode and command source presence/absence. When Pr. 77 = 2, write is enabled.
(Refer to the parameter list on page 78) Parameter clear is disabled.
∗3
Enabled only when stopped by the PU. At a PU stop, PS is displayed on the operation panel. As set in Pr. 75 Reset selection/PU stop selection. (Refer to page 165)
Operation mode
Operation
X12 Signal
Mode
OFF ∗1
ON
If Network operation frequency setting and start
signal are entered, operation is performed in that
OFF ∗1
ON
status.
Network ∗2
OFF
ON
During stop
ON
OFF
OFF
ON
During operation
ON
OFF
Output stop
of the operation panel resets the inverter.
Operation Mode
PU Operation
Operation mode setting
Function/Operation
Parameter write is enabled (depending on Pr. 77
Parameter write selection and each parameter write
conditions (Refer to page 78 for the parameter list))
Parameter write is disabled
(Note that the Pr.297 setting is available when Pr.296 ≠
"9999.")
>
Operating Status
output stop
operation
NET Operation
×
Δ ∗3
×
∗1
× ∗2
×
×
×
×
× ∗2
×
: Enabled, ×: Disabled, Δ: Some are enabled
Parameter write
Switching to PU
Operation Mode
Disallowed
Disallowed
Allowed
Disallowed
Disallowed
Disallowed
∗1
4
51