Monitor display and monitor output signal
(6)
Selecting the decimal digits for the monitor (Pr. 268)
As the operation panel display is 4 digits long, the decimal places may vary at analog input, etc. The decimal places can
be hidden by selecting the decimal digits.
In such a case, the decimal digits can be selected by Pr. 268.
Pr. 268 Setting
9999 (initial value)
No function
For the first or second decimal places (0.1 increments or 0.01 increments) of the monitor, numbers in the first
0
decimal place and smaller are rounded to display an integral value (1 increments).The monitor value smaller than
0.99 is displayed as 0.
When 2 decimal places (0.01 increments) are monitored, the 0.01 decimal place is dropped and the monitor
1
displays the first decimal place (0.1 increments). The monitored digits in 1 increments are displayed as they are.
REMARKS
The number of display digits on the cumulative energization time (Pr. 52 = "20"), actual operation time (Pr. 52 = "23"), and
cumulative power (Pr. 52 = "25") does not change.
Parameters referred to
Pr. 30 Regenerative function selection, Pr. 70 Special regenerative brake duty
Pr. 37 Speed display