Parameter clear/ All parameter clear

5.21 Parameter clear/ All parameter clear

POINT
Set "1" in Pr.CL Parameter clear or ALLC all parameter clear to initialize all parameters. (Parameters are not
cleared when "1" is set in Pr. 77 Parameter write selection.)
Refer to the extended parameter list on page 78 for parameters cleared with this operation.
Operation
1.
Screen at power-ON
The inverter starts up in the Network operation
mode. The monitor display appears.
2.
Change the X12 signal (Bit11) setting to "1."
X12 signal (Bit11) gives a control input
command through FL remote communication.
3.
Press
to choose the PU operation mode.
4.
Press
to choose the parameter setting
mode.
5.
Turn
until
6.
Press
to read the currently set value.
"
"(initial value) appears.
7.
Turn
to change it to the set value "
8.
Press
to set.
Turn
Press
Press
Setting
0
Not executed.
Set parameters back to the initial values. Refer to the parameter list on page 78 for availability of
1
parameter clear and all parameter clear.
REMARKS
and
The inverter is not in the PU operation mode. Carry out operation from step 2 again.
186
(
) appears.
".
Flicker ··· Parameter setting complete!!
to read another parameter.
to show the setting again.
twice to show the next parameter.
Description
are displayed alternately ... Why?
Display
PU indicator is lit.
PRM indicator is lit.
(The parameter number read previously appears.)
Parameter clear
All parameter clear
Parameter clear
All parameter clear