Parameter list
Func-
Parameter
Name
tion
Automatic restart after instantaneous
162
power failure selection
Stall prevention operation level for
165
restart
—
168
Parameter for manufacturer setting. Do not set.
—
169
170
Watt-hour meter clear
171
Operation hour meter clear
User group registered display/batch
172
clear
173
User group registration
174
User group clear
—
178
—
179
—
180
—
181
—
182
—
183
—
184
—
190
—
191
Parameter for manufacturer setting. Do not set.
—
192
—
232
—
233
—
234
—
235
—
236
—
237
—
238
—
239
—
240
Soft-PWM operation selection
—
241
Parameter for manufacturer setting. Do not set.
—
244
Cooling fan operation selection
245
Rated slip
246
Slip compensation time constant
Constant-power range slip
247
compensation selection
—
249
Earth (ground) fault detection at start
—
250
Stop selection
—
251
Output phase loss protection selection
255
Life alarm status display
256
Inrush current limit circuit life display
257
Control circuit capacitor life display
258
Main circuit capacitor life display
259
Main circuit capacitor life measuring
261
Power failure stop selection
—
267
Parameter for manufacturer setting. Do not set.
—
268
Monitor decimal digits selection
—
269
Parameter for manufacturer setting. Do not set.
—
270
Stop-on contact control selection
84
Minimum
Refer
Initial
Setting Range
Setting
to
Value
Increments
Page
0, 1, 10, 11
1
1
151
0 to 200%
0.1%
150%
151
0, 10, 9999
1
9999
147
0, 9999
1
9999
147
9999, (0 to 16)
1
0
167
0 to 999, 9999
1
9999
167
0 to 999, 9999
1
9999
167
0, 1
1
1
163
0, 1
1
1
176
0 to 50%, 9999
0.01%
9999
100
0.01 to 10s
0.01s
0.5s
100
0, 9999
1
9999
100
0, 1
1
0
160
0 to 100s,
1000 to 1100s,
0.1s
9999
138
8888, 9999
0, 1
1
1
160
(0 to 15)
1
0
177
(0 to 100%)
1%
100%
177
(0 to 100%)
1%
100%
177
(0 to 100%)
1%
100%
177
0, 1 (2, 3, 8, 9)
1
0
177
0, 1, 2
1
0
156
0, 1, 9999
1
9999
147
0, 1
1
0
139
Control Mode-based
Customer
Correspondence Table
Parameter
Setting
V/F
V/F
V/F
162
165
168
Parameter for manufacturer setting. Do not set.
169
170
171
172
173
174
178
179
180
181
182
183
184
190
191
Parameter for manufacturer setting. Do not set.
192
232
233
234
235
236
237
238
239
240
241
Parameter for manufacturer setting. Do not set.
244
245
246
247
249
250
251
255
256
257
258
259
261
267
Parameter for manufacturer setting. Do not set.
268
269
Parameter for manufacturer setting. Do not set.
×
270
Parameter
Clear
All clear
AD MFVC
AD MFVC
AD MFVC
GP MFVC
GP MFVC
GP MFVC
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
Parameter list
5