Measurement of main circuit voltages, currents and powers

7.2
Measurement of main circuit voltages, currents and powers
Since the voltages and currents on the inverter power supply and output sides include harmonics, measurement data
depends on the instruments used and circuits measured.
When instruments for commercial frequency are used for measurement, measure the following circuits with the instruments
given on the next page.
When installing meters etc. on the inverter output side
When the inverter-to-motor wiring length is large, especially in the 400V class, small-capacity models, the meters and CTs
may generate heat due to line-to-line leakage current. Therefore, choose the equipment which has enough allowance for
the current rating.
Three-phase
power supply
Instrument types
218
Input voltage
Input current
Inverter
Ar
W11
R/L1
Vr
W12
As
S/L2
Vs
W13
At
T/L3
Vt
V
+
Examples of Measuring Points and Instruments
U
Au
W21
Vu
V
Av
Vv
Aw
W
W22
Vw
-
Output voltage
Output current
To the motor
: Moving-iron type
: Electrodynamometer type
: Moving-coil type
: Rectifier type