Mitsubishi Electric 700 Series Instruction Manual page 90

Hide thumbs Also See for 700 Series:
Table of Contents

Advertisement

Parameter list
Func-
Parameter
Name
tion
30
Regenerative function selection
31
Frequency jump 1A
32
Frequency jump 1B
33
Frequency jump 2A
34
Frequency jump 2B
35
Frequency jump 3A
36
Frequency jump 3B
37
Speed display
40
RUN key rotation direction selection
41
Up-to-frequency sensitivity
42
Output frequency detection
Output frequency detection for reverse
43
rotation
44
Second acceleration/deceleration time
45
Second deceleration time
46
Second torque boost
47
Second V/F (base frequency)
Second stall prevention operation
48
current
51
Second electronic thermal O/L relay
52
DU/PU main display data selection
54
55
Parameter for manufacturer setting. Do not set.
56
57
Restart coasting time
58
Restart cushion time
59
Remote function selection
60
Energy saving control selection
61
Reference current
62
Reference value at acceleration
63
Reference value at deceleration
65
Retry selection
Stall prevention operation reduction
66
starting frequency
67
Number of retries at fault occurrence
68
Retry waiting time
69
Retry count display erase
70
Special regenerative brake duty
71
Applied motor
72
PWM frequency selection
73
Parameter for manufacturer setting. Do not set.
74
75
Reset selection/PU stop selection
77
Parameter write selection
∗6
78
Reverse rotation prevention selection
79
Parameter for manufacturer setting. Do not set.
80
Minimum
Refer
Initial
Setting Range
Setting
to
Value
Increments
Page
136,
0, 1, 2
1
0
151
0 to 400Hz, 9999
0.01Hz
9999
106
0 to 400Hz, 9999
0.01Hz
9999
106
0 to 400Hz, 9999
0.01Hz
9999
106
0 to 400Hz, 9999
0.01Hz
9999
106
0 to 400Hz, 9999
0.01Hz
9999
106
0 to 400Hz, 9999
0.01Hz
9999
106
0, 0.01 to 9998
0.001
0
146
0, 1
1
0
182
0 to 100%
0.1%
10%
144
0 to 400Hz
0.01Hz
6Hz
144
0 to 400Hz, 9999
0.01Hz
9999
144
0 to 3600/360s
0.1/0.01s
5/10/15s
116
∗2
0 to 3600/360s, 9999
0.1/0.01s
9999
116
0 to 30%, 9999
0.1%
9999
94
0 to 400Hz, 9999
0.01Hz
9999
107
0 to 200%, 9999
0.1%
9999
101
0 to 500A, 9999
0.01A
9999
123
0, 5, 7 to 12, 14, 20,
23 to 25, 52 to 57, 61,
1
0
147
62, 100
0, 0.1 to 5s, 9999
0.1s
9999
151
0 to 60s
0.1s
1s
151
0, 1, 2, 3
1
0
113
0, 9
1
0
162
0 to 500A, 9999
0.01A
9999
121
0 to 200%, 9999
1%
9999
121
0 to 200%, 9999
1%
9999
121
0 to 5
1
0
158
0 to 400Hz
0.01Hz
60Hz
101
0 to 10, 101 to 110
1
0
158
0.1 to 360s
0.1s
1s
158
0
1
0
158
0 to 30%
0.1%
0%
136
95, 98,
0, 1, 3 to 6, 13 to 16, 23,
1
0
125,
24, 40, 43, 44, 50, 53, 54
127,
0 to 15
1
1
163
0 to 3, 14 to 17
1
14
165
0, 1, 2
1
0
166
0, 1, 2
1
0
167
Control Mode-based
Customer
Correspondence Table
Parameter
Setting
V/F
V/F
V/F
30
31
32
33
34
35
36
37
40
41
42
43
44
45
46
47
48
51
52
54
55
Parameter for manufacturer setting. Do not set.
56
57
58
59
60
61
62
63
65
66
67
68
69
70
71
72
73
Parameter for manufacturer setting. Do not set.
74
75
77
78
79
Parameter for manufacturer setting. Do not set.
Parameter
Clear
All clear
AD MFVC
AD MFVC
AD MFVC
GP MFVC
GP MFVC
GP MFVC
×
×
×
×
×
×
×
×
Parameter list
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents