Mitsubishi Electric 700 Series Instruction Manual page 66

Hide thumbs Also See for 700 Series:
Table of Contents

Advertisement

(1)
Common memory area 1
Input data
256 words
(Inverter→master)
(512 bytes)
Output data
256 words
(Master→inverter)
(512 bytes)
Virtual address
(byte boundary)
H00000000
H00000008
Input data
H00000010
(Inverter→master)
H000001F0
H000001F8
H00000200
H00000208
Output data
H00000210
(Master→inverter)
H000003F0
H000003F8
*
When accessing a message, the access size should be the size stated in the table above.
REMARKS
When node status is other than "during FL remote network remote operation", all output data is changed to "0".
(Refer to page 49 for change of the setting.)
When transmitting a message, common memory area 1 and 2 are read only. (Refer to page 62)
(2)
Common memory area 2
Control information (inverter→master)
Control information (master→inverter)
Virtual address
(byte boundary)
H00000400
H00000402
H00000404
(1) Control information
(inverter
master)
H00000BE0
H00000BE2
H00000BE4
H00000C00
H00000C02
H00000C04
(2) Control information
(master
inverter)
H000013E0
H000013E2
H000013E4
*
When accessing a message, the access size should be the size stated in the table above.
REMARKS
When sending a message, common memory area 1 and 2 are read only. (Refer to page 62)
Size
Data to be sent from inverter to master (4 words).
The data includes inverter status, output frequency, etc.
Data to be sent from master to inverter (4 words).
The data includes starting command, frequency command, etc.
Address
(word boundary)
0
4
8
248
252
256
260
264
504
508
1024 words (2048 bytes)
1024 words (2048 bytes)
Address
(word boundary)
0
1
2
1008
1009
1010
1024
1025
1026
2032
2033
2034
Description
Applications
Size
(word boundary)
4
Input data (#1)
4
Input data (#2)
4
Input data (#3)
:
4
Input data (#63)
4
Input data (#64)
4
Output data (#1)
4
Output data (#2)
4
Output data (#3)
:
4
Output data (#63)
4
Output data (#64)
Size
Applications
Size
(Number in parentheses
(word boundary)
indicates node address.)
1
Slave status (#)
1
Actual status slave type (#1)
14
Simple setting check area (#1)
:
1
Slave status (#64)
1
Actual status slave type (#64)
14
Simple setting check area (#64)
1
Remote control area (#1)
1
Expected slave type (#1)
14
Simple setting area (#1)
:
1
Remote control area (#64)
1
Expected slave type (#64)
14
Simple setting area (#64)
Cyclic transmission
Refer to
Page
59
57
Description
(Number in parentheses
indicates node address)
Description
4
55

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents