Chapter 4 – Controls
Figure 4.37 – Set Date and Time Screen
If you need to change the time, press the TIME corre-
sponding function key (F6) and a passcode box will pop
up. Enter the passcode: 5759. Spin the rotary control
knob until the correct digit is shown, then press the knob
to proceed to the next digit. After the correct passcode is
entered, press the SET key.
Figure 4.38 – Enter Code
The SET TIME box will pop up (Figure 4.39). To change
the setting, turn the rotary control knob clockwise to
increase the value, or turn the knob counter-clockwise
to decrease the value. When the correct value is shown,
press the rotary control knob to proceed to the next value.
When all values are correct, press the SET key.
26
Figure 4.39 – Set Time
To change the time, turn the rotary control knob clockwise
to increase the value, or turn the knob counter-clockwise
to decrease the value. When the correct value is shown,
press the rotary control knob to proceed to the next value.
When the correct time is entered, press the SET key (#8,
Figure 4.30).
If you need to change the DATE, press the DATE cor-
responding function key (F5) and the passcode box will
pop up again. Enter the same passcode as described
above an press the SET key. Follow the same procedure
described above to set the correct date.
Finally, press the function key F8 (Figure 4.30) to confirm
the new setting (shown also as #5 in Figure 4.36). To abort
the changes, press the ESC key.
Note
All settings are password protected. The Password "5759"
Depending on which function key was pushed (F5 for
DATE or F6 for TIME), a SET TIME or SET DATE box
will pop up.
The above procedure can also be used to change the
brightness, language, or unit of measure.
For more detailed instructions, refer to the WIKA Mobile
Control Qscale i2 Operators Manual.

System Bypass

If the LMI system is in a lockout status and the machine
must be operated, the LMI system can be bypassed by
removing the panel behind the operator's seat (held in
place by 7 screws) and then turning the LMI key to the
OFF position. Once the problem has been rectified, the
LMI system can be re-enabled by turning the LMI key
back to the ON position.