LD 73
Define Group 2 Error Thresholds
Prompt
Response
REQ
NEW
TYPE
DTI2
FEAT
LPTI
...
GP2
20
(Aggregate
count default
[20x128ms=2.
5sec])
...
OOS2
1-(15)-255s
NNC2
1-(15)-255s
MNT2
1-(15)-255s
PERS
50
CLRS
50
OOSC
1-(5)-255
For example, if the total cumulative time that an error has been present
reaches the aggregate time (2.5 sec default) in less than the time set in OOS,
the card is put into an out-of-service state. If it took more than the preset time
for the error condition to register, the card could be put into NNDC, NNC or
MAINT states. The card remains in the alarm condition until the error has
improved and after the Group 2 guard timers expire.
Define Group 2 Error Thresholds
You are able to define Group 2 error thresholds in LD 73. Only the highest
priority Group 2 alarm condition is active at a time. The order of priority
(from highest to lowest) is: LOS, AIS, LFAS, LMAS, RAI.
Description
New
2.0 Mb/s DTI
data block
Loop Timer
100s
(Maintenance
threshold)
(Group 2 guard timer)
(Group 2 guard timer)
(Group 2 guard timer)
(in multiples of 2ms)
(in multiples of 2ms)
(Out of service count limit) After
this number is reached, the
card does not auto-enable.
PRI Maintenance
12s
12s
(NNDC
(NNC
threshold)
threshold)
Option 11C
Page 97 of 126
4s
(OOS
threshold)
2.0 Mb DTI/PRI