Prompt
Response
CRC
NC mt dt ct ot
BPV
NB mt dt ct ot
FAP
NF mt dt ct ot
SLP
NS mt dt ct ot
nnnM = time in minutes where nnn = 1-240
nnH = time in hours where nn = 1-24
Description
Cyclic redundancy check error counts
NC=Error count values are in the range 1-255
mt = Maintenance threshold time (MNT)
dt = No new data calls threshold time (NNDC)
ct = No new calls threshold time (NNC)
ot = Out of service threshold time (OOS).
Note: The following requirements must be met for input
mt = Maintenance threshold must be equal to or greater than
dt.
dt = Data calls threshold must be equal to or greater than ct.
ct = Calls threshold must be equal to or greater than ot.
Bipolar violation error counts
NB = Error count values are in the range 1-255
mt = Maintenance threshold time (MNT)
dt = No new data calls threshold time (NNDC)
ct = No new calls threshold time (NNC)
ot = Out of service threshold time (OOS).
Note: The following requirements must be met for this input:
mt = >dt = >ct = >ot.
Frame alignment problem thresholds
NF = Error count values are in the range 1-255
mt = Maintenance threshold time (MNT)
dt = No new data calls threshold time (NNDC)
ct = No new calls threshold time (NNC)
ot = Out of service threshold time Note: The following
requirements must be met for this input: mt = >dt = >ct = >ot.
Maintenance threshold slip count
NS = Error count values are in the range 1-255
mt = Maintenance threshold time (MNT)
dt = No new data calls threshold time (NNDC)
ct = No new calls threshold time (NNC)
ot = Out of service threshold time (OOS).
2.0 Mb DTI Implementation
Option 11C
Page 27 of 126
2.0 Mb DTI/PRI