Nortel Meridian 1 Option 11C Manual page 77

2.0 mb dti/pri
Hide thumbs Also See for Meridian 1 Option 11C:
Table of Contents

Advertisement

Table 24
Self-test failure codes for NTAK10 2.0 Mb DTI (Part 1 of 5)
DTI009 loop
DTI/PRI loop or channel failed hardware self test. For
ch
DTI009 L M E, the output data is
DTI009C ch
DTI Card C or channel ch of Card C failed hardware
self-test.
Error codes for NI microprocessor (M=N):
00 = NI self test has finished.
01 = Undefined messout received
02 = Problem with group 2 error handling (invalid level)
03 = NI to CI FIFO full (128 messages lost)
04 = CI-1 Micro failed to initialize on power-up
05 = NI group 1 error handling - undefined condition
found
06 = Bad MESSOUT number 6 encountered.
07 = NI Messout queue is full.
08 = NI Messin queue full.
09 = NI priority Messin queue is full.
10 = Bad MESSOUT number 10 encountered.
11 = TN = 0 read from regular queue.
12 = TN = 0 read from priority queue.
14 = Bad TN associated with MESSOUT number 14
15 = Bad TN associated with MESSOUT number 15
DTI Maintenance
L = loop
M = N for NI microprocessor
M = C for CI microprocessor
E = error code for debug purposes.
Page 77 of 126