Nortel Meridian 1 Option 11C Manual page 60

2.0 mb dti/pri
Hide thumbs Also See for Meridian 1 Option 11C:
Table of Contents

Advertisement

Page 60 of 126
2.0 Mb PRI Implementation
PREF CC4
41-49
SREF CC4
41-49
CCAR
0-(15)
LD 73 – Define PRI parameters and thresholds.
Prompt
Response
REQ
CHG
TYPE
PRI2
FEAT
LPTI
LOOP
X
MFF
AFF (CRC)
ALRM
(REG) ALT
G10S
SLP
mc mt oc ot
BPV
n1 n2
CRC
n1 n2
FAP
n1 n2
RATS
1-(10)-15
553-3011-315
Standard 13.00
Card slot number of PRI2 card containing the prImary clock
reference for IP Expansion cabinet 4.
Card slot number of PRI2 card containing the secondary clock
reference for IP Expansion cabinet 4.
Clock Controller Audit Rate.
Enter the time (in minutes) between normal CC audits.
Description
Change data
2.0 Mb PRI
X is the slot number of the 2.0 Mb PRI card.
Alternate mode or CRC multi-frame mode
Default or alternate alarms selected
Slip error count,
mc = Maintenance threshold slip count, 1- (5)-255
mt = Maintenance threshold time, default 24 hours, see Note
after Step 3
oc = Out-of-service threshold slip count, 1-(30)-255
ot = Out of service threshold time, default 1 hour, see Note after
Step 3
Bipolar violation error count, 1-(128)-255 for n1, 1-(122)-255 for
n2.
n1 is multiplied by 16 to obtain the actual count, giving an actual
count range of 16-4080.
Cyclic redundancy check error count 1-(201)-255 for n1,
1-(97)-255 for n2.
n1 is multiplied by 4 to obtain the actual count, giving an actual
count range of 4-1020.
Frame alignment problem error count 1-(28)-255 for n1, (1)-255
for n2.
Number of seconds firmware has to check BPV/CRC/FAP for
excessive error rate.
January 2002