Nortel Meridian 1 Option 11C Manual page 62

2.0 mb dti/pri
Hide thumbs Also See for Meridian 1 Option 11C:
Table of Contents

Advertisement

Page 62 of 126
2.0 Mb PRI Implementation
LD 73 – Change trunk pad category values.
Prompt
Response
REQ
CHG
TYPE
PRI2
FEAT
PADS
PDCA
#
The following prompts define the pad levels.
The receiving pad code is r and the transmission pad code is t. These entries have the range
0-15. The pad values (in decibels) relating to these codes are shown after this table.
ONP
r t
DSET
r t
OPX
r t
DTT
r t
SDTT
r t
NTC
r t
TRC
r t
DCO
r t
VNL
r t
DTO
r t
ACO
r t
AFX
r t
ADD
r t
SATT
r t
ATO
r t
PRI2
r t
XUT
r t
XEM
r t
553-3011-315
Standard 13.00
Description
Change data
2.0 Mb PRI
PAD table-0 is default and is hard coded
On-premises extension
Meridian Digital set
(prompted only if the 2.0 Mb Gateway feature is equipped
Off-premises extension
Digital TIE trunks
Digital Satellite TIE trunks
Nontransmission compensated
Transmission compensated
Digital COT, FEX, WAT, and DID trunks
Via Net Loss
2.0 Mb PRI2 digital TOLL office trunks
Analog CO or WATS trunks
Analog FEX trunks
Analog DID trunks
Analog satellite TIE trunks
Analog TOLL office trunks
2.0 Mb PRI trunk
(prompted only if the 1.5/2.0 Mb Gateway feature is equipped
and TYPE=2.0 Mb PRI)
Analog CO trunk
(prompted only if the 1.5/2.0 Mb Gateway feature is equipped
and TYPE=PRI2)
Analog TIE trunk
(prompted only if the 1.5/2.0 Mb Gateway feature is equipped
and TYPE=PRI2)
January 2002

Advertisement

Table of Contents
loading