2.0 Mb DTI Implementation
Prompt
Response
GP2
T2 mt dt ct ot
FRFW
YES (NO)
LD 73 – Define the 2.0 Mb DTI system timers.
Prompt
Response
REQ
NEW
CHG
TYPE
DTI2
FEAT
SYTI
MAND
0-(15)-1440
NCSD
0-(15)-1440
1S-59S
OSGD
0-(15)-1440
OOSC
0-(5)-127
PERS
0-(100)-254
DBNC
(10)-32
CC0
1-9
<CR>
X
PREF CC0
1-9
553-3011-315
Standard 13.00
Description
Group 2 error thresholds.
This is the maximum amount of time that can occur before
software checks the associated thresholds of 120 to 32,640
msec and rounds it to the closest multiple of 128 msec. T2
error count values are in the range
1-(20)-255.
NC = Error count values are in the range 1-255
mt = Maintenance threshold time (MNT)
dt = No new data calls threshold time (NNDC)
ct = No new calls threshold time (NNC)
ot = Out of service threshold time (OOS).
Note: The following requirements must be met for this input:
mt = >dt = >ct = >ot.
This 2.0 Mb DTI card is (is not) equipped with special
Firmware for France.
Description
Add or Change Digital Trunk Interface data block
2.0 Mb DTI
Change the switch timers and counters for 2.0 Mb DTI.
There is only one such block per switch.
Maintenance guard time in minutes.
New call suppression guard time in minutes and seconds.
Out of service guard time in minutes.
Out of service occurrences since midnight (DTI disabled).
Persistence timer in milliseconds for far end problems.
Debounce timer in milliseconds
Card number for clock controller 0.
No change for defaults
To remove clock controller data
Slot number of the DTI2 card containing the primary clock
reference for the main cabinet (this is the system clock.)