Monitor Option 11C DTI operation

Maintenance messages

2.0 Mb DTI Error messages

5
Software enable all NTAK10 2.0 Mb DTI cards using LD 60 (command
ENLL N, where N is the 2.0 Mb DTI card number).
6
Software enable the clock controller using LD 60 (ENL CC 0).
7
Enable clock tracking on primary digital loop by issuing the following
command TRCK PCK.
The 2.0 Mb DTI status and error conditions are reported in the following
types of messages, as shown in Table . Additional information on DTI
messages can be found in the X11 System Messages Guide (553-3001-411).
Table 20
Maintenance messages
Message
DTA
DTI
The Digital Trunk Interface diagnostic program (LD 60) is used to maintain
the NTAK10 2.0 Mb DTI Interface Card.
Comprehensive lists of the self-test failure codes for the NTAK10 2.0 Mb
DTI follow the self-test description, later in this chapter.
DTI Maintenance
Meaning
Digital Trunk Alarms (Resident Monitor)
Digital Trunk Interface