Daikin GYEQ20AN Service Manual page 227

Gas heat pump air conditioner heat recovery r-410a 50 hz
Table of Contents

Advertisement

SiAUY361411EA
3
Replacing the air cleaner element
Part name Element
Tools/materials Waste cloth
Step
(1) See "Basics" (page 213)
(2) Remove the element
cover and the element
(3) Inspect the element
mounting portion
(4) Install the element and
element cover
▼Air cleaner element mounting portion
Element
Maintenance / Service Data
1. Loosen the element cover clamps, and remove the element cover
and element holder.
2. Remove the center wing nut, and remove the element.
Clean the air cleaner interior and element mounting
portion if stained.
1. Fit the new element with the center bolt, and tighten it with the wing
nut.
2. Install the element holder and the element cover with its top face
(marked with an arrow) oriented upward.
Element cover
Task
Mount the cover with its top face (marked
with an arrow) oriented upward
Center wing nut
Maintenance
Remarks
• The cover is clamped
with two lock plate
clamps.
• Take care not to drop
the wing nuts or other
parts.
• Keep away from
surrounding protrusions
or edges.
• Take care not to drop
any parts.
• Clamped with three lock
plates.
023326-00E
216