Installation site requirements of the outdoor unit..................48 6.2.2 Additional installation site requirements of the outdoor unit in cold climates..........50 6.2.3 Installation site requirements of the indoor unit ..................51 Installer reference guide ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 3
About electrical compliance........................... 92 7.9.3 Precautions when connecting the electrical wiring..................93 7.9.4 Guidelines when connecting the electrical wiring..................93 7.9.5 Specifications of standard wiring components....................94 ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 4
To remove the water filter ..........................194 11.5.2 To clean the water filter in case of trouble....................194 11.5.3 To install the water filter ..........................196 Installer reference guide ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 5
Table 3 – Minimum venting opening area for natural ventilation: indoor unit ............222 14.8 ESP curve: Indoor unit..............................224 15 Glossary 16 Field settings table ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Indicates a situation that could result in minor or moderate injury. NOTICE Indicates a situation that could result in equipment or property damage. INFORMATION Indicates useful tips or additional information. Symbols used on the unit: ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Improper installation or attachment of equipment or accessories could result in electrical shock, short-circuit, leaks, fire or other damage to the equipment. Only use accessories, optional equipment and spare parts made or approved by Daikin. WARNING Make sure installation, testing and applied materials comply with applicable legislation (on top of the instructions described in the Daikin documentation).
Corrosion of copper pipes or soldered parts may cause the refrigerant to leak. 1.2.3 Refrigerant If applicable. See the installation manual or installer reference guide of your application for more information. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 9
Make sure there is no oxygen in the system. Refrigerant may only be charged after performing the leak test and the vacuum drying. Possible consequence: Self-combustion and explosion of the compressor because of oxygen going into the operating compressor. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
70°C. In case of a brine leak, hot parts inside the unit can create a hazardous situation. WARNING The use and installation of the application MUST comply with the safety and environmental precautions specified in the applicable legislation. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
When installing the earth leakage protector, make sure it is compatible with the inverter (resistant to high frequency electric noise) to avoid unnecessary opening of the earth leakage protector. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 12
Running the product in reversed phase can break the compressor and other parts. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
The original documentation is written in English. All other languages are translations. Technical engineering data ▪ A subset of the latest technical data is available on the regional Daikin website (publicly accessible). ▪ The full set of latest technical data is available on the Daikin Business Portal (authentication required).
Page 14
Note: There is also an installer settings table in the user reference guide. This table has to be filled in by the installer and handed over to the user. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
1 Handle the unit using the sling to the left and the handle to the right. Pull up both sides of the sling at the same time to prevent disconnection of the sling from the unit. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Fluorinated greenhouse gases label c Multilingual fluorinated greenhouse gases label d Energy label e Unit mounting plate f Bolts, nuts, washers, spring washers and wire clamp ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Handles at the back of the unit Handles at the bottom of the unit. Carefully tilt the unit to the back so that the handles become visible. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Explanation European split outdoor pair heat pump Medium water temperature – ambient zone: −10~−20°C Refrigerant R32 Capacity class Model series Power supply A=Austrian model [—]=Non-Austrian model ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
It is recommended to install this option in colder regions with possible low ambient temperatures or heavy snowfall. For installation instructions, see the installation manual of the drain pan heater. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Space heating/cooling On/OFF output ▪ Changeover to external heat source For installation instructions, see the installation manual of the digital I/O PCB and addendum book for optional equipment. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 21
For providing space heating/cooling, it is possible to use heat pump convectors (FWXV). For installation instructions, see the installation manual of the heat pump convectors, and the addendum book for optional equipment. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
For installation instructions, see the installation manual of the LAN adapter. 4.3.3 Possible combinations of indoor unit and outdoor unit Indoor unit Outdoor unit ERGA04 ERGA06 ERGA08 EHVH/X04 — — EHVH/X08 — ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
In case an external room thermostat is used and room frost protection needs to be guaranteed in all conditions, then you have to set Emergency [9.5] to Automatic. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
For your daily needs, you can use preset values and schedules. To deviate from your daily needs, you can temporarily overrule the preset values and schedules, or use the holiday mode. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 25
Code: [C-05] heating or cooling demand. Benefits ▪ Wireless. The Daikin external room thermostat is available in a wireless version. ▪ Efficiency. Although the external room thermostat only sends ON/OFF signals, it is specifically designed for the heat pump system. ▪...
Page 26
▪ Cooling. The heat pump convector offers, besides heating capacity, also excellent cooling capacity. ▪ Efficiency. Optimal energy efficiency because of the interlink function. ▪ Stylish. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 27
ON/ ▪ #: [2.A] OFF condition. No separation between ▪ Code: [C-05] heating or cooling demand. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
A thermostatic valve is installed before the underfloor heating in each of the other rooms. INFORMATION Mind situations where the main room can be heated by another heating source. Example: Fireplaces. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 29
Configuration Setting Value Unit temperature control: 0 (Leaving water): Unit operation is decided based on the leaving water ▪ #: [2.9] temperature. ▪ Code: [C-07] ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 30
Unit operation is decided by the ▪ #: [2.9] external thermostat. ▪ Code: [C-07] Number of water temperature zones: 0 (Single zone): Main ▪ #: [4.4] ▪ Code: [7-02] ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 31
EKVKHPC on each heat pump convector. Configuration Setting Value Unit temperature control: 0 (Leaving water): Unit operation is decided based on the leaving water ▪ #: [2.9] temperature. ▪ Code: [C-07] ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Bed rooms (additional zone) Heat pump convectors: ▪ In heating: 45°C ▪ In cooling: 12°C Setup A Additional leaving water temperature zone B Room 1 C Room 2 ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 33
External room thermostat for the convector can only send a thermo ON/ additional zone: OFF condition. No separation between ▪ #: [3.A] heating or cooling demand. ▪ Code: [C-06] ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
During heating operation of the auxiliary boiler, the auxiliary boiler operates to achieve the desired water temperature set via the auxiliary boiler controller. Setup ▪ Integrate the auxiliary boiler as follows: ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 35
Make sure the auxiliary boiler and its integration in the system complies with applicable legislation. ▪ Daikin is NOT responsible for incorrect or unsafe situations in the auxiliary boiler system. ▪ Make sure the return water to the heat pump does NOT exceed 55°C. To do so: Set the desired water temperature via the auxiliary boiler controller to maximum 55°C.
Page 36
NOT influenced or turned ON/OFF by direct sunlight. ▪ Frequent changeover may cause corrosion of the auxiliary boiler. Contact the manufacturer of the auxiliary boiler for more information. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Are there any other domestic hot water — needs? Example: If the DHW consumption of a family (4 persons) per day is as follows: ▪ 3 showers ▪ 1 bath ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 38
ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
DHW pump (field supply) d Heater element (field supply) e Non‑return valve (field supply) f Shower (field supply) g Cold water h Domestic hot water OUT i Recirculation connection ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
▪ Setup and configuration: No additional equipment needed. 5.5.2 Consumed energy You can use the following methods to determine the consumed energy: ▪ Calculating ▪ Measuring ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Backup heater supplied from a three- (*6V (6T1): 3~ 230 V) phase grid (i.e. the backup heater (*9W: 3N~ 400 V) model is *9W or *6V connected to a three-phase grid) ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
5.5.4 Preferential kWh rate power supply General rule ▪ Power meter 1: Measures the outdoor unit. ▪ Power meter 2: Measures the rest (i.e. indoor unit and backup heater). ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
The power limitation level can be expressed as: Maximum running current (in A) Maximum power input (in kW) ▪ The power limitation level can be activated: Permanently By digital inputs ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
5.6.2 Power limitation activated by digital inputs Power limitation is also useful in combination with an energy management system. The power or current of the entire Daikin system is limited dynamically by digital inputs (maximum four steps). Each power limitation level is set via the user interface by limiting one of the following: ▪...
Turns OFF the outdoor unit. Example If the configuration is as follows: Power limitation level does NOT allow operation of backup heater (step 1). Then power consumption is limited as follows: ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
When the power saving functionality of the outdoor unit is active, the outdoor unit is turned down to reduce standby energy losses. As a result, the outdoor ambient temperature is NOT read out. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 47
To protect the outdoor unit, the internal sensor of the outdoor unit is always used. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Refrigerant piping requirements (length, height difference). See further in this "Preparation" chapter. Mind the following spacing guidelines: >250 >350 >250 >250 (mm) (mm) Air outlet Air inlet ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 49
In places where a mineral oil mist, spray or vapour may be present in the atmosphere. Plastic parts may deteriorate and fall off or cause water leakage. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Sweden, … 1 Remove the screws holding the suction grille. 2 Remove the suction grille, and dispose of it. 3 Reattach the screws to the unit. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
NOT affected by the snow. If necessary, install a snow cover or shed and a pedestal. 6.2.3 Installation site requirements of the indoor unit INFORMATION Also read the precautions and requirements in the "General safety precautions" chapter. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 52
Do NOT use means to accelerate the defrosting process or to clean the equipment, other than those recommended by the manufacturer. ▪ Be aware that R32 refrigerant does NOT contain an odour. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 53
Joints made in installation between parts of refrigerant system shall be accessible for maintenance purposes. WARNING Make sure installation, servicing, maintenance and repair comply with instructions from Daikin and with applicable legislation (for example national gas regulation) and are executed only by authorised persons. NOTICE ▪...
Page 54
▪ Ventilation openings to the outside are NOT considered suitable ventilation openings (the user can block them when it is cold). ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
6.4 Preparing water piping ▪ Valve towards expansion vessel. The valve towards the expansion vessel (if equipped) MUST be open. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
▪ Water pressure. The maximum water pressure is 4 bar. Provide adequate safeguards in the water circuit to ensure that the maximum pressure is NOT exceeded. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 57
Non-brass metallic piping. When using non-brass metallic piping, insulate the brass and non-brass properly so that they do NOT make contact with each other. This to prevent galvanic corrosion. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Minimum water volume For EHVH*, there are no requirements for the minimum water volume. For EHVX*, check that the total water volume in the installation is minimum 10 litres. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 59
Use the following graph to determine the maximum water volume for the calculated pre-pressure. Pre-pressure (bar) Maximum water volume (l) Example: Maximum water volume and expansion vessel pre-pressure ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
"9.4 Checklist during commissioning" [ 181]. 6.4.4 Changing the pre-pressure of the expansion vessel NOTICE Only a licensed installer may adjust the pre-pressure of the expansion vessel. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Because 250 l is lower than 290 l, the expansion vessel is appropriate for the installation. 6.5 Preparing electrical wiring 6.5.1 About preparing electrical wiring INFORMATION Also read the precautions and requirements in the "General safety precautions" chapter. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
The indoor unit is designed to receive an input signal by which the unit switches into forced off mode. At that moment, the outdoor unit compressor will not operate. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
6.5.4 Overview of electrical connections for external and internal actuators Item Description Wires Maximum running current Outdoor unit and indoor unit power supply Power supply for outdoor 2+GND unit ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 64
More technical specifications of the different connections are indicated on the inside of the indoor unit. Backup heater type Power supply Required number of conductors 1N~ 230 V 2+GND ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 65
Preparation Backup heater type Power supply Required number of conductors 1N~ 230 V (6V) 2+GND 3~ 230 V (6T1) 3+GND 3N~ 400 V 4+GND ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
DANGER: RISK OF ELECTROCUTION Do NOT leave the unit unattended when the service cover is removed. 7.2.2 To open the outdoor unit DANGER: RISK OF ELECTROCUTION ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
2 Remove the user interface panel. Open the hinges at the top and slide the top panel upwards. NOTICE If you remove the user interface panel, also disconnect the cables from the back of the user interface panel to prevent damage. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 68
▪ When you need access to the high voltage switch box 2× 5 If you need access to the high voltage components, remove the high voltage switch box cover. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
2 Tilt the switch box to the front and lift it out of its hinges. 2× 3 Place the switch box lower on the unit. Use the 2 hinges located lower on the unit. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Additionally, make sure the unit is positioned at least 100 mm above the maximum expected level of snow. INFORMATION The maximum height of the upper protruding part of the bolts is 15 mm. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 71
Option 2: On plastic mounting feet In this case, you can use the bolts, nuts, washers and spring washers delivered with the unit as accessories. 0 mm ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 72
The EKFT008D option kit is recommended in areas with heavy snowfall. 4× (mm) a Maximum snowfall height b EKFT008D option kit c Anti-vibration rubber (field supply) ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Air outlet NOTICE Properly align the unit. Make sure the backside of the unit does NOT protrude. 3 Remove the protective cardboard and instruction sheet. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
In short, the drain pan must be installed level (with a tolerance of 1° at all sides) and as follows: a Drain pan b U-beams ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
In case the unit is installed in places where strong wind can tilt the unit, take following measure: 1 Prepare 2 cables as indicated in the following illustration (field supply). 2 Place the 2 cables over the outdoor unit. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
3 Slide the indoor unit into position. 4 Adjust the height of the leveling feet to compensate for floor irregularities. The maximum allowed deviation is 1°. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
4 Reattach the side panel. Ensure the water can flow through the drain tube. It is recommended to use a tundish to collect the water. Option 1: Through the left side panel 3× ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
7.5.2 Precautions when connecting the refrigerant piping INFORMATION Also read the precautions and requirements in the following chapters: ▪ General safety precautions ▪ Preparation DANGER: RISK OF BURNING ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
ALWAYS use 2 wrenches together when loosening a flare nut. ▪ ALWAYS use a spanner and torque wrench together to tighten the flare nut when connecting the piping. This to prevent nut cracking and leaks. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Flare tool for R32 Conventional flare tool (clutch type) Clutch type Wing nut type (Ridgid-type) (Imperial-type) 0~0.5 mm 1.0~1.5 mm 1.5~2.0 mm 5 Check that the flaring is properly made. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
The following figure shows the stop valve parts required when handling the valve. Service port and service port cap Valve stem Field piping connection Stem cap ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 82
After handling the stop valve, tighten the stem cap, and check for refrigerant leaks. Item Tightening torque (N∙m) Stem cap, liquid side 13.5~16.5 Stem cap, gas side 22.5~27.5 ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
7.5.9 To connect the refrigerant piping to the indoor unit 1 Connect the liquid stop valve from the outdoor unit to the refrigerant liquid connection of the indoor unit. Refrigerant liquid connection ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
NOTICE Use this vacuum pump for R32 exclusively. Using the same pump for other refrigerants may damage the pump and the unit. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
2 Leave as is for 4-5 minutes and check the pressure: If the pressure… Then… Does not change There is no moisture in the system. This procedure is finished. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Typical workflow – Charging additional refrigerant typically consists of the following stages: 1 Determining if and how much you have to charge additionally. 2 If necessary, charging additional refrigerant. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
R=(total length (m) of liquid piping – 1 0 m)×0.020 R=Additional charge (kg) (rounded in units of 0.01 kg) INFORMATION Piping length is the one-way length of liquid piping. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Use the GWP value mentioned on the refrigerant charge label. That GWP is based on the current legislation on fluorinated greenhouse gases. The GWP mentioned in the manual might be outdated. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
1 Install the shut-off valves on the space heating water pipes. 2 Screw the indoor unit nuts on the shut-off valve. 3 Connect the domestic hot water in and out pipes to the indoor unit. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 90
A pressure relief valve (field supply) with an opening pressure of maximum 10 bar (=1 MPa) must be installed on the domestic cold water inlet connection in accordance with the applicable legislation. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
7.8.6 To fill the domestic hot water tank 1 Open every hot water tap in turn to purge air from the system pipe work. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Equipment complying with EN/IEC 61000‑3‑12 (European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤75 A per phase.). ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Round crimp-style terminal ▪ Use the following methods for installing wires: Wire type Installation method Single-core wire AA´ A´ a Curled single-core wire b Screw c Flat washer ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
7.9.6 To connect the electrical wiring to the outdoor unit 1 Remove the switch box cover. 2× ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 95
1× 1× 6 Connect an earth leakage circuit breaker and fuse to the power supply line. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
4 Seal the low voltage wiring intake using the sealing tape (delivered as accessory). Without low voltage cables With low voltage cables 7.9.8 To connect the main power supply 1 Connect the main power supply. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 98
The preferential kWh rate power supply contact is connected to the same terminals (X5M/9+10) as the safety thermostat. Thus, the system can have EITHER preferential kWh rate power supply OR a safety thermostat. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Factory-mounted cable connected to the contactor of the backup heater, inside the switch box (K1M for *3V models, K5M for *6V and *9W models) Field wiring (see table below) ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 100
230 V AC *6V (6V: 1N~ 230 V) Q1DI 1N~, 50 Hz 230 V AC *6V (6T1: 3~ 230 V) Q1DI 3~, 50 Hz L1 L2 L3 230 V AC ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
1 Connect the valve control cable to the appropriate terminals as shown in the illustration below. NOTICE Wiring is different for a NC (normally closed) valve and a NO (normally open) valve. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
2 Fix the cable with cable ties to the cable tie mountings. 7.9.13 To connect the alarm output 1 Connect the alarm output cable to the appropriate terminals as shown in the illustration below. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
7.9.15 To connect the changeover to external heat source 1 Connect the changeover to external heat source cable to the appropriate terminals as shown in the illustration below. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
7.9.17 To connect the safety thermostat (normally closed contact) 1 Connect the safety thermostat (normally closed) cable to the appropriate terminals as shown in the illustration below. 9 10 ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
7.11.1 To close the indoor unit 1 Close the cover of the switch box. 2 Put the switch box back into place. 3 Reinstall the top panel. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 106
6 Reconnect the cables to the user interface panel. 7 Reinstall the user interface panel. NOTICE When closing the indoor unit cover, make sure that the tightening torque does NOT exceed 4.1 N•m. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
"8.7 Menu structure: Overview installer settings" [ 179] 8.1.1 To access the most used commands To change the user permission level You can change the user permission level as follows: ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 108
1 Set the user permission level to Installer. See "To change — the user permission level" [ 107]. 2 Go to [9.I]: Installer settings > Overview field settings. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
(use the breadcrumbs). For the setting… Refer to… Language [7.1] Time/date [7.2] Hours — Minutes Year Month System ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
18 Feb 2018 22:19 Possible actions on this screen Go through the list of the main menu. Go to the main menu screen. Enable/disable breadcrumbs. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 112
▪ : Fancoil unit ▪ : Radiator g2 Leaving water temperature setpoint g3 Room thermostat type: ▪ : Daikin user interface used as room thermostat ▪ : External control ▪ Hidden: Leaving water temperature control g4 Measured room temperature Additional...
Shows the applicable symbol for your unit. cooling Put the unit in heating mode or cooling mode. You cannot change the mode on heating only models. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
[2] Main zone screen °C °C – – Room Main zone [3] Additional zone screen [5] Tank temperature screen °C °C – – Tank Additional zone ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Go to the next setting. Confirm changes and proceed. 8.3.7 Schedule screen: Example This example shows how to set a room temperature schedule in heating mode for the main zone. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 116
To clear the content of the week schedule 1 Select the name of the current schedule. User defined 1 2 Select Delete. Delete Rename Select 3 Select OK to confirm. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 117
In this example, Monday is the first day you programmed. Thus, the last programmed action is valid up to the first action of next Monday. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 118
5 Repeat this action for all other weekdays. — User defined 1 To program the schedule for Saturday and copy it to Sunday 1 Select Saturday. 2 Select Edit. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 119
The schedule name can contain up to 15 characters. 5 Confirm the new name. INFORMATION Not all schedules can be renamed. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
See "8.4.4 Using weather-dependent curves" [ 123]. 8.4.2 2-points curve Define the weather-dependent curve with these two setpoints: ▪ Setpoint (X1, Y2) ▪ Setpoint (X2, Y1) ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Examples Weather-dependent curve when slope is selected: ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 122
The icon corresponds to the heat emitter for that zone: ▪ : Underfloor heating ▪ : Fan coil unit ▪ : Radiator ▪ : Domestic hot water tank ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
[2.5] Main zone > Heating WD curve Main zone – Cooling [2.6] Main zone > Cooling WD curve Additional zone – Heating [3.5] Additional zone > Heating WD curve ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
[2.9]. Perform actions according to the table below. Main zone unit control method [2.9] Description Leaving water temperature control Room frost protection is NOT guaranteed. ([C‑07]=0) ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 126
The unit will supply leaving water to the the outdoor ambient temperature heat emitters to heat up the room drops below 4°C again, and the leaving water temperature setpoint will be lowered. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 127
Room frost protection is active even if the user does NOT confirm emergency operation. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Influence of the LWT setpoint mode [2.4] is as follows: ▪ In Fixed LWT setpoint mode, the scheduled actions consist of desired leaving water temperatures, either preset or custom. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 129
10°C. Heating WD curve Set weather-dependent heating for the main zone (if [2.4]=1 or 2): ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 130
Note: This value should be lower than [1‑02] as for high outdoor temperatures less warm water is required. Cooling WD curve Set weather-dependent cooling for the main zone (if [2.4]=2): ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 131
It is important to set Emitter type correctly and in accordance with your system layout. The target delta T for the main zone depends on it. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 132
Setpoint range To prevent a wrong (i.e. too hot or too cold) leaving water temperature for the main leaving water temperature zone, limit its temperature range. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 133
Leaving water temperature range for the main leaving water temperature zone (= the leaving water temperature zone with the lowest leaving water temperature in heating operation and the highest leaving water temperature in cooling operation) ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 134
If an external room thermostat is used, the external room thermostat will control the room frost protection. However, the room frost protection is only possible if [C.2] Space heating/cooling=On. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 135
In heating, the target delta T will only be achieved after some operation time, when the setpoint is being reached, because of the big difference between leaving water temperature setpoint and inlet temperature at startup. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 136
[2.C.1] [8‑05] Modulation: ▪ 0 No (disabled) ▪ 1 Yes (enabled) Note: The desired leaving water temperature can only be read out on the user interface. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 137
The shut off valve: ▪ 0 No: is NOT influenced by heating or cooling demand. ▪ 1 Yes: closes when there is NO heating or cooling demand. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Example" [ 115]. Setpoint mode The setpoint mode of the additional zone can be independently set from the setpoint mode of the main zone. "Setpoint mode" [ 129]. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 139
Note: This value should be lower than [0‑01] as for high outdoor temperatures less warm water is required. Cooling WD curve Set weather-dependent cooling for the additional zone (if [3.4]=2): ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 140
Additional zone range [9‑05]~[9‑06] [1‑0C] 0: Underfloor Maximum 55°C Variable (see [3.B.1]) heating 1: Fancoil unit Maximum 55°C Variable (see [3.B.1]) 2: Radiator Maximum 65°C Fixed 10°C ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 141
Leaving water. ▪ External room thermostat if the control type of the main zone is: External room thermostat,or Room thermostat. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
To check which space operation mode is currently used The space operation mode is displayed on the home screen: ▪ When the unit is in heating mode, the icon is shown. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 143
Operation mode=Automatic, and ▪ Operation mode schedule=Reversible. The unit determines its operation mode in such a way that it will always stay within the following operation ranges: ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 144
Changeover settings related to the indoor temperature. Only applicable when Automatic is selected and the system is configured in room thermostat control with 1 leaving water temperature zone and quick heat emitters. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 145
Code Description [4.4] [7‑02] ▪ 0: Single zone Only one leaving water temperature zone: a Main LWT zone ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 146
When the space heating/cooling operation is OFF, the pump is always OFF. When space heating/cooling operation is ON, you have the choice between these operation modes: ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 147
Sample is ONLY available in leaving water temperature control. a Space heating/cooling control b Off c On d LWT temperature e Actual f Desired g Pump operation ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 148
With this limitation range, delta T is possible and the comfort is guaranteed. The maximum values depend on the unit type: ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 149
Use this setting to compensate for possible heat losses of the building due to the evaporation of melted ice or snow. (e.g. in cold region countries). ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
1 Go to [5.1]: Tank > Powerful operation 2 Turn powerful operation Off or On. Usage example: You immediately need more hot water If you are in the following situation: ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 151
Reheat setpoint: ▪ 30°C~min(50,[6‑0E])°C Schedule You can set the tank temperature schedule using the schedule screen. For more information about this screen, see "8.3.7 Schedule screen: Example" [ 115]. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 153
The maximum temperature that users can select for the domestic hot water. You can use this setting to limit the temperatures at the hot water taps. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
By default, daylight savings time is enabled and clock format is set to 24 hours. If you want to change these settings, you can do this in the menu structure (User settings > Time/date) once the unit is initialised. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 157
You can: ▪ Completely deactivate quiet mode ▪ Manually activate a quiet mode level until the next scheduled action ▪ Use and program a quiet mode schedule ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 158
Only applicable in combination with the bivalent function. See also "Bivalent" [ 173]. Code Description [7.5.1] Electricity price > High [7.5.2] Electricity price > Medium [7.5.3] Electricity price > Low [7.6] Gas price ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 159
An incentive can be taken into account when setting the energy prices. Although the running cost can increase, the total operation cost, taking into account the reimbursement will be optimized. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
[7.5.1]=17 8.5.8 Information Dealer information The installer can fill in his contact number here. Code Description [8.3] Number that users can call in case of problems. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
• [E-05]: Can the system prepare domestic hot water? • [E-06]: Is a domestic hot water tank installed in the system? • [E-07]: What kind of domestic hot water tank is installed? ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 162
When measuring the resistance value of each heater, you can set the exact heater capacity and this will lead to more accurate energy data. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 163
[6‑03]+[6‑04]. INFORMATION If [4‑0A]=3 and emergency mode is active, the power usage of the backup heater is maximal and equal to 2×[6‑03]+[6‑04]. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 164
Only for systems with integrated domestic hot water tank: If the storage temperature setpoint is higher than 50°C, Daikin recommends NOT to disable the backup heater second step because it will have a big impact on the required time for the unit to heat up the domestic hot water tank.
Page 165
NOT confirm emergency operation. Balancing Priorities For systems with an integrated domestic hot water tank. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 166
[8-04]. Range: 0~10 hours Remark: The minimum time is 0.5 hours even when the selected value is 0. [9.6.5] Minimum running timer: Do NOT change. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 167
Maximum running time domestic hot water Water pipe freeze prevention Only relevant for installations with water piping outdoors. This function tries to protect outdoor water piping from freezing. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 168
Therefore, always enable the auto restart function. ▪ 3 Safety thermostat: A safety thermostat is connected to the system (normal closed contact) ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 169
Type: ▪ 0 Amp: The limitation values are set in A. ▪ 1 kW: The limitation values are set in kW. Limit when [9.9.1]=Continuous and [9.9.2]=Amp: ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 172
The average timer corrects the influence of ambient temperature variations. The weather-dependent setpoint calculation is done on the average outdoor temperature. The outdoor temperature is averaged over the selected time period. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 173
I/O PCB). When it is activated, the contact X1, X2 is closed and open when it is deactivated. See illustration below for the schematic location of this contact. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 174
Permission signal X1–X2 [C-04] [C-03] Outdoor temperature [C-03] Bivalent ON temperature (fixed) Auxiliary boiler active Auxiliary boiler inactive Possibility 2: Based on the outdoor temperature and energy prices ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 175
CAUTION Make sure to observe all rules mentioned in application guideline 5 when bivalent operation function is enabled. Daikin shall NOT be held liable for any damage resulting from failure to observe this rule. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 –...
Page 176
Afterwards: An installer can manually disable the protective functions by setting [9.G]: Disable protections=Yes. After his work is done, he can enable the protective functions by setting [9.G]: Disable protections=No. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Description [C.1] Room: ▪ 0: Off ▪ 1: On [C.2] Space heating/cooling: ▪ 0: Off ▪ 1: On [C.3] Tank: ▪ 0: Off ▪ 1: On ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Only accessible by installer (***) Only applicable when WLAN adapter is installed INFORMATION Depending on the selected installer settings and unit type, settings will be visible/ invisible. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Solar kit settings are shown but are NOT applicable for this unit. Settings shall NOT be used or changed. INFORMATION Depending on the selected installer settings and unit type, settings will be visible/ invisible. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
After the installation of the unit, first check the items listed below. Once all checks are fulfilled, the unit must be closed. Power-up the unit after it is closed. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
To perform an air purge. To perform a test run. To perform an actuator test run. Underfloor screed dryout function The underfloor screed dryout function is started (if necessary). ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
During air purge function, pump speed limitation [9‑0D] is NOT applicable. The air purge function automatically stops after 30 minutes. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 183
Result: The air purge starts. It stops automatically when done. 6 To stop the air purge manually: — 1 In the menu, go to Stop air purge. 2 Select OK to confirm. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Result: The actuator test run starts. It stops automatically when ready (±30 min). To stop the test run manually: — 1 In the menu, go to Stop test run. 2 Select OK to confirm. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
▪ checking the proper functioning of the setup on a regular basis, ▪ performing the correct program complying with the type of the used screed. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 186
Scroll through the schedule. ▪ Adjust the duration (between 1 and 72 hours) and temperatures (between 15°C and 55°C). 4 Press the left dial to save the schedule. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 187
When the program is stopped due to an error, an operation switch-off, or a power failure, you can read out the underfloor heating screed dryout status: ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 188
If the UFH screed dryout program was stopped due to a power failure and the power resumes, the program will automatically restart the last implemented step. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Show the user what to do for the maintenance of the unit. ▪ Explain the user about energy saving tips as described in the operation manual. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
11.4 Checklist for yearly maintenance of the indoor unit Check the following at least once a year: ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 191
▪ ALWAYS first unscrew the drain cap, and connect a drain hose to the bottom of the water filter, then open the drain valve. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 192
Using an ohmmeter, check if contactors K1M, K2M, K3M and K5M (depending on your installation) operate correctly. All contacts of these contactors must be in open position when the power is turned OFF. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
3 Remove the stop from the access point to the tank. 4 Use a drain hose and a pump to drain the tank via the access point. Access point to the tank ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
11.5.2 To clean the water filter in case of trouble 1 Remove the water filter from the unit. See "11.5.1 To remove the water filter" [ 194]. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 195
Correctly install the strainer in the magnetic filter/dirt separator housing using the protrusions. Rolled‑up filter Strainer Protrusion 5 Install and properly tighten the bottom of the water filter housing. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Make sure to open the valve (if equipped) towards the expansion vessel, otherwise the overpressure will be generated. 5 Open the stop valves and add water to the water circuit if needed. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
MUST NOT be supplied through an external switching device, such as a timer, or connected to a circuit that is regularly turned ON and OFF by the utility. DANGER: RISK OF BURNING ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Make sure that the water volume in the too low installation is above the minimum required value (see "6.4.3 To check the water volume and flow rate" [ 58]). ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
If yes, make sure that the room where you want to purge air is sufficiently ventilated. Reason: Refrigerant might leak into the water circuit, and subsequently into the room when you purge air from the heat emitters or collectors. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
0 m. The maximum water circuit head is 10 m. Check the installation requirements. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
> Backup heater > Equilibrium temperature [5‑01] There is air in the system. Purge air manually or automatically. See the air purge function in the chapter "9 Commissioning" [ 180]. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
The disinfection function was Program the start-up of the disinfection interrupted by domestic hot water function when the coming 4 hours NO tapping domestic hot water tapping is expected. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Result: A short description of the error and the error code is displayed on the screen. 2 Press in the error screen. Result: A long description of the error is displayed on the screen. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
OU: Malfunction of discharge pipe thermistor OU: Malfunction of heat exchanger thermistor OU: Malfunction of heat exchanger thermistor OU: Electrical box temperature rise problem ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 205
Abnormal increase outlet water temperature (DHW) Abnormal increase outlet water temperature Overheating water circuit (thermostat) Backup heater overheated External backup heater overheated Tank disinfection function not completed correctly ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 206
No connection with room thermostat Indoor unit, outdoor unit matching problem Tank type problem Extension/hydro mismatch problem Communication problem between control box and option box ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 207
Error AJ-03 is reset automatically from the moment there is a normal tank heat-up. INFORMATION The user interface of the indoor unit will display how to reset an error code. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
4 After 5 to 10 minutes (after only 1 or 2 minutes in case of very low ambient temperatures (<−10°C)), close the liquid stop valve with a hexagonal wrench. 5 Check on the manifold if the vacuum is reached. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
DIP switches SW5, SW6 and SW2 back to their original position. 11 Reattach the service PCB cover and switch box cover and turn the power back ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 210
5°C (see temperature read out of the indoor unit). You can achieve this, for example, by activating all fans of the fan coil units. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Technical data 14 Technical data A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is available on the Daikin Business Portal (authentication required). 14.1 Piping diagram: Outdoor unit 7.0 CuT...
(3) Legend Connector Capacitor Rectifier bridge Connector Connector Connector Fuse T 6.3 A 250 V FU1, FU2 Fuse T 3.15 A 250 V Fuse T 30 A 250 V Connector IPM* Intelligent power module ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 214
U, V, W Connector V3, V4, V401 Varistor Connector Terminal strip Electronic expansion valve Solenoid valve (4-way valve) Noise filter (ferrite core) Noise filter # Field supply ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Main leaving water temperature On/OFF thermostat (wired) On/OFF thermostat (wired) On/OFF thermostat (wireless) On/OFF thermostat (wireless) Ext. thermistor External thermistor Heat pump convector Heat pump convector ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 216
F1U, F2U (A4P) * Fuse 5 A 250 V for digital I/O PCB FU1 (A1P) Fuse T 5 A 250 V for PCB FU2 (A10P) Fuse T 1.6 A 250 V for PCB ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 217
SW3~SW5 (A12P) Push buttons Power supply transformer # Backup heater power supply terminal strip X*, X*A, X*Y, Y* Connector Terminal strip * Optional # Field supply ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 218
Normally open Safety thermostat contact: 16 V DC Safety thermostat contact: 16 V DC detection (voltage supplied by PCB) detection (voltage supplied by PCB) Shut-off valve Shut-off valve ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 219
Only for heat pump convector Only for heat pump convector Only for wired On/OFF thermostat Only for wired On/OFF thermostat Only for wireless On/OFF thermostat Only for wireless On/OFF thermostat ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 220
4 signal 2 core Only for remote user interface 2x0.75 X5M: 11-12 A14P: P1-P2 user interface communication 2 core 2x0.75 A13P: P1-P2 LAN adapter communication 4D128739 ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 222
14.7 Table 3 – Minimum venting opening area for natural ventilation: indoor unit dm=m –m (kg) Minimum venting opening area (cm H=600 mm 1.80 1.60 1.40 1.20 1.00 0.80 0.60 0.40 0.20 ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Page 223
For intermediate dm values (i.e. when dm is between two dm values from the table), consider the value that corresponds to the higher dm value from the table. If dm=1.55 kg, consider the value that corresponds to "dm=1.6 kg". ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
See also the minimum and maximum allowed water flow range in the technical specifications. ▪ Water quality must be according to EU directive 98/83 EC. ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7 Installer reference guide Daikin Altherma 3 R F 4P618947-1 – 2020.03...
Optional equipment Equipment made or approved by Daikin that can be combined with the product according to the instructions in the accompanying documentation. Field supply Equipment NOT made by Daikin that can be combined with the product according to the instructions in the accompanying documentation.
2/10 Field settings table Installer setting at variance with default value Breadcrumb Field code Setting name Range, step Date Value Default value Room └─ Antifrost 1.4.1 [2-06] Activation 0: Disabled 1: Enabled 1.4.2 [2-05] Room setpoint 4~16°C, step: 1°C 12°C └─...
Page 228
3/10 Field settings table Installer setting at variance with default value Breadcrumb Field code Setting name Range, step Date Value Default value Additional zone [2-0D] Emitter type 0: Underfloor heating 1: Fancoil unit 2: Radiator └─ Setpoint range 3.8.1 [9-05] Heating minimum 15~37°C, step: 1°C 25°C...
Page 229
4/10 Field settings table Installer setting at variance with default value Breadcrumb Field code Setting name Range, step Date Value Default value [0-0B] Leaving water value for high ambient temp. for DHW WD curve. 35~[6-0E]°C, step: 1°C 55°C [0-0C] Leaving water value for low ambient temp. for DHW WD curve. 45~[6-0E]°C, step: 1°C 60°C [0-0D]...
Page 230
5/10 Field settings table Installer setting at variance with default value Breadcrumb Field code Setting name Range, step Date Value Default value [0-04] Leaving water value for high ambient temp. for LWT add zone cooling WD curve. [9-07]~[9-08]°C, step: 1°C 8°C [0-05] Leaving water value for low ambient temp.
Page 231
6/10 Field settings table Installer setting at variance with default value Breadcrumb Field code Setting name Range, step Date Value Default value 9.9.2 [4-09] Type 0: Current 1: Power 9.9.3 [5-05] Limit 0~50 A, step: 1 A 50 A 9.9.4 [5-05] Limit 1 0~50 A, step: 1 A...
Page 232
7/10 Field settings table Installer setting at variance with default value Breadcrumb Field code Setting name Range, step Date Value Default value [1-04] Weather dependent cooling of the main leaving water temperature zone. 0: Disabled 1: Enabled [1-05] Weather dependent cooling of the additional leaving water temperature zone 0: Disabled 1: Enabled [1-06]...
Page 233
8/10 Field settings table Installer setting at variance with default value Breadcrumb Field code Setting name Range, step Date Value Default value [4-0A] Backup heater configuration 0: 1 (*1) 1: 1/1+2 (*2) (*3) 2: 1/2 3: 1/2 + 1/1+2 in emergency [4-0B] Automatic cooling/heating changeover hysteresis.
Page 234
9/10 Field settings table Installer setting at variance with default value Breadcrumb Field code Setting name Range, step Date Value Default value [8-05] Allow modulation of the LWT to control the room temp? 0: No 1: Yes [8-06] Leaving water temperature maximum modulation. 0~10°C, step: 1°C 5°C [8-07]...
Page 235
10/10 Field settings table Installer setting at variance with default value Breadcrumb Field code Setting name Range, step Date Value Default value [D-08] Is an external kWh meter used for power measurement? 0: No 1: 0,1 pulse/kWh 2: 1 pulse/kWh 3: 10 pulse/kWh 4: 100 pulse/kWh 5: 1000 pulse/kWh...
Page 236
4P618947-1 2020.03 Verantwortung für Energie und Umwelt...