SiAUY361411EA
Inspect the self-starter motor by measuring the resistance between its terminals and the ground.
Between S terminal and ground
Between M terminal and ground
Check if the ring gear and self-starter motor pinion engage smoothly while operating them with
the actuator check function. If they do not smoothly engage or the ring gear end face is
damaged, inspect the self-starter motor itself as instructed above.
Parts Inspection
Inspecting the self-starter motor
Measuring points
S terminal
Inspecting the Outdoor Unit
Measured value
0.2 Ω
0.2 Ω
M terminal
025942-00E